Simulation and experimental validation of single-phase series active power filter using PI and backstepping nonlinear controllers
نویسندگان
چکیده
منابع مشابه
Compensation Strategies for Shunt Active Power Filter in Single- and Three-Phase Systems: Different Formulation, Comparison and Evaluation
متن کامل
simulation and experimental studies for prediction mineral scale formation in oil field during mixing of injection and formation water
abstract: mineral scaling in oil and gas production equipment is one of the most important problem that occurs while water injection and it has been recognized to be a major operational problem. the incompatibility between injected and formation waters may result in inorganic scale precipitation in the equipment and reservoir and then reduction of oil production rate and water injection rate. ...
Single-Phase Shunt Active Power Filter Using Indirect Control Method
A single-phase shunt active power filter is used mainly for the elimination of harmonics in single-phase AC networks. In this paper a single-phase shunt active power filter based on, an indirect control technique is designed and simulated. This control technique is achieved by phase shifting the input signal(voltage/current) by π/2.The overall action of the shunt active power filter to eliminat...
متن کاملIndirect Control of Single-Phase Active Power Filters using Harmonic Control Arrays
The ever increase of nonlinear loads in electric distribution networks causes many problems due to the high level of harmonic currents. This paper proposes a new technique for controlling a single phase shunt active power filter based on a selective compensation using the newly developed technique of harmonic control arrays. Simulation results confirm the appropriate selective harmonic compensa...
متن کاملNonlinear Control of Single-Phase Shunt Active Power filter Theoretical analysis of closed-loop performances
The problem of controlling single-phase shunt active power filter is addressed in presence of nonlinear loads. The control objective is twofold: (i) compensation of harmonic and reactive currents absorbed by the nonlinear load; (ii) regulation of the inverter output capacitor voltage. A two-loop cascade control strategy is developed that includes an inner-loop designed, using the backstepping t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Applied Power Engineering (IJAPE)
سال: 2020
ISSN: 2722-2624,2252-8792
DOI: 10.11591/ijape.v9.i1.pp78-88