Simulation and Analysis of Double Pipe Heat Exchanger
نویسندگان
چکیده
منابع مشابه
Heat Transfer of Nanofluid in a Double Pipe Heat Exchanger
This paper investigates the enhancement of heat transfer coefficient and Nusselt number of a nanofluid containing nanoparticles (γ-AL2O3) with a particle size of 20 nm and volume fraction of 0.1%-0.3% (V/V). Effects of temperature and concentration of nanoparticles on Nusselt number changes and heat transfer coefficient in a double pipe heat exchanger with counter turbulent flow are investigate...
متن کاملAn experimental investigation of heat transfer of Fe2O3/Water nanofluid in a double pipe heat exchanger
One way to increase the heat transfer is to use perforated twisted tapes with different hole diameters, which largely improve heat transfer with an increase in the heat transfer area at the constant volume and more mixed flow. In the previous studies, the effect of nanofluids with perforated twisted tapes is less studied. In this work, the performance of water / iron oxide nanofluid in a double...
متن کاملAn experimental investigation of heat transfer of Fe2O3/Water nanofluid in a double pipe heat exchanger
One way to increase the heat transfer is to use perforated twisted tapes with different hole diameters, which largely improve heat transfer with an increase in the heat transfer area at the constant volume and more mixed flow. In the previous studies, the effect of nanofluids with perforated twisted tapes is less studied. In this work, the performance of water / iron oxide nanofluid in a double...
متن کاملLaminar Flow Heat Transfer of a Pseudoplastic Fluid through a Double Pipe Heat Exchanger
An experimental study was carried out to obtain the mean convective heat transfer coefficient of aqueous carboximethyl cellulose (CMC) solutions in double-pipe heat <span style="font-size: 10pt; color:...
متن کاملAnalysis of Heat Transfer Coefficient of CuO/Water Nanofluid using Double Pipe Heat Exchanger
Experimental investigations of heat transfer coefficient of CuO/Water nanofluid are reported in this paper. The heat transfer coefficient of the CuO/water was measured with the help of double pipe heat exchanger. The nanofluid was prepared by dispersing a CuOnano particle in deionized water. CuO/water nanofluid with a nominal diameter of 27nm at different volume concentrations (0.1 &0.3 vol.%) ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal for Research in Applied Science and Engineering Technology
سال: 2021
ISSN: 2321-9653
DOI: 10.22214/ijraset.2021.35554