Simplified model for partially-composite precast concrete insulated wall panels subjected to lateral loading
نویسندگان
چکیده
منابع مشابه
Composite Behavior of Insulated Concrete Sandwich Wall Panels Subjected to Wind Pressure and Suction
A full-scale experimental test was conducted to analyze the composite behavior of insulated concrete sandwich wall panels (ICSWPs) subjected to wind pressure and suction. The experimental program was composed of three groups of ICSWP specimens, each with a different type of insulation and number of glass-fiber-reinforced polymer (GFRP) shear grids. The degree of composite action of each specime...
متن کاملConnections for Precast Concrete Load-bearing Shear Wall Panels
Precast load-bearing shear wall panels are used extensively for high-rise construction because of the ease and speed of assembly, and the high quality of the precast panels. The connections between panels are extremely important since they affect both the speed of erection '~md the overall integrity of the structure. This paper presents the results of a four-year research program conducted to i...
متن کاملSimplified Calculation Model and Experimental Study of Latticed Concrete-Gypsum Composite Panels
In order to address the performance complexity of the various constituent materials of (dense-column) latticed concrete-gypsum composite panels and the difficulty in the determination of the various elastic constants, this paper presented a detailed structural analysis of the (dense-column) latticed concrete-gypsum composite panel and proposed a feasible technical solution to simplified calcula...
متن کاملFoam Concrete Precast Elements in Composite Concrete-GFRP Plate Girders
This paper is focused on using foam concrete as structural element in polymer-concrete composite plate girders. Trial mixes of foam concrete and different proportions of foam agent were considered to obtain the suitable mix that can be used as structural element in composite girders system. Details of the experimental investigations on foam concrete precast slabs and polymer-concrete composite ...
متن کاملConcrete Filled Tubular Bracing Subjected to Cyclic Loading
The energy absorption of concrete filled, hollow-steel bracing was analyzed respect to geometric and mechanical parameters including the width-to-thickness section ratio, slenderness level, and strength of the steel and concrete. Local buckling and ductility were also investigated with respect to variation in the cross-section. The infill increased the compression resistance, even after multipl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Engineering Structures
سال: 2017
ISSN: 0141-0296
DOI: 10.1016/j.engstruct.2017.01.065