Simplified Efficiency Calibration Methods for Semiconductor Detectors used in Criticality Dosimetry
نویسندگان
چکیده
منابع مشابه
Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties
Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...
متن کاملComparison of TLD calibration methods for 192Ir dosimetry
For the purpose of dose measurement using a high-dose rate (192)Ir source, four methods of thermoluminescent dosimeter (TLD) calibration were investigated. Three of the four calibration methods used the (192)Ir source. Dwell times were calculated to deliver 1 Gy to the TLDs irradiated either in air or water. Dwell time calculations were confirmed by direct measurement using an ionization chambe...
متن کاملComparison of the Obtained Results from Two Calibration Methods in MRI Brachytherapy Normoxic Polymer Gel Dosimetry
Introduction: Despite the fact that the clinical implementation of polymer gel dosimetry has been facilitated after the introduction of normoxic gels, there are still complications in its clinical routine use that are under investigation. In the current work, the feasibility of using a normoxic polymer gel dosimeter named MAGICA has been investigated for use in our clinical brachytherapy applic...
متن کاملMaterial Identification Methods in Spectral Radiography Using CdTe Semiconductor Detectors
Material identification in radiography is traditionally performed by dualenergy systems, using double exposure technique or two-layers detectors. Performance of such systems results from the closeness of the materials to be discriminated, from photonic noise, and energetic discriminating power of the detector. For difficult problems such as explosive detection in luggage, conventional dual-ener...
متن کاملSemiconductor Detectors for Nuclear Spectrometry *
Please make the following corrections on subject report. Figures 3-2 and 3-3 should be replaced by the attached figures. Page 91, line 12 should be changed to read "The Fano factor established by these measurements is .30 ± 0.03 which is entirely consistent with the approximate value of 0.32 derived from Van Roosbroeck's curves."
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Social Science Research Network
سال: 2022
ISSN: ['1556-5068']
DOI: https://doi.org/10.2139/ssrn.4139758