Simplified determination of fluoride ion in wastewater by an ion selective electrode.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of fluoride in wine by fluoride selective ion electrode, standard addition method: collaborative study.

The accuracy, precision, and reproducibility of a rapid method for determination of fluoride in wine, using a fluoride selective ion electrode, were established by a collaborative study involving 12 laboratories, 5 in Europe and 7 in the United States. The laboratories assayed 6 Youden pairs of fluoride-fortified, red and white wine samples with fluoride concentrations ranging from 0.2 to 3.0 m...

متن کامل

Measurements with fluoride ion selective electrode

Where E0 is the standard electrode potential, R is the universal gas constant, T is the absolute temperature, z is the number of moles of electrons transferred in the cell reaction or halfreaction, F is the Faraday-constant, and cox and cred are the concentrations of the oxidized and reduced forms of the component. The potential of the hydrogen electrode is declared to be 0.000 V at all tempera...

متن کامل

Determination of Copper Content of Human Blood Plasma by an Ion Selective Electrode based on a New Copper-Selectophore

A new selectophore was introduced for Cu2+ ions. Spectroscopic studies showed a selectivity of a new organic compound (L) toward copper ions and several transitional metal ions. Hence, L was utilized in designing several ion selective electrodes for these cations. In practice, Cu2+ ion selective electrode behaved Nernstian (slope of 27.95±0.3 mV decade-1) over a...

متن کامل

Construction of an Ion-Selective Eelectrode for Determination of permanganate Ion

A PVC ion-selective membrane electrode based on Cd-tetraphenyl porphyrine as a carrier was prepared fordetermination of MnO4- ion. This electrode revealed good selectivity toward permanganate ion over a widevariety of anions. Effects of some experimental parameters such as nature of the plasticizer, the amounts ofcarrier and additive, and concentration of the internal solution on the potential ...

متن کامل

Validation of an ion selective electrode system for the analysis of serum fluoride ion

A high impedance unit was developed for use with a fluoride/pH electrode system for the measurement of serum fluoride. The linearity, accuracy, precision and detection limit of the system is reported. At a pH of 1.55, the system was linear over a range of serum fluoride concentrations up to 100 mumol l(-1), with a lower limit of detection of 0.3 mumol l(-1). Recoveries at this pH were 94-105% i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BUNSEKI KAGAKU

سال: 1988

ISSN: 0525-1931

DOI: 10.2116/bunsekikagaku.37.5_t61