Simple Pretreatment Method for Tritium Measurement in Environmental Water Samples using a Liquid Scintillation Counter
نویسندگان
چکیده
The aim of this study is to evaluate quantitatively the effectiveness ion exchange resins and activated carbon in tritium measurement. A standard water sample was adjusted a concentration 5 Bq L−1. This stirred with cation (PCH) anion (PAO) carbon. After stirring samples, supernatant each filtered through 0.45 µm membrane filters. electrical conductivity an experimental condition, where amounts PCH, PAO, were 0.3 g, 0.6 respectively, lower than that treated by distillation method. method requires approximately 12 h process; however, same level results achieved min. experiment within deviation. These suggested proposed batch involving had negligible effect on total organic for samples decreased demonstrate impurity removal from resins.
منابع مشابه
Optimization Method to Determine Gross Alpha-Beta in Water Samples Using Liquid Scintillation Counter
Liquid scintillation counting (LSC) is an adequate nuclear technique to determine radioactivity levels, as verified by this study for the determination of the gross alpha and beta activities of aqueous samples because of its simplicity and low associated cost comparison with other techniques. This paper discusses a new approach to the monitoring of gross alpha and gross beta activities in water...
متن کاملTritium Determination in Danube River Water in Serbia by Liquid Scintillation Counter
Tritium activity concentration in Danube river water in Serbia has been determinate using a liquid scintillation counter Quantulus 1220. During December 2010, water samples were taken along the entire course of Danube through Serbia, from HungarianSerbian to Romanian-Serbian border. This investigation is very important because of the nearness of nuclear reactor Paks in Hungary. Sample preparati...
متن کاملMeasurement of 90sr in aqueous samples using liquid scintillation counting with full spectrum DPM method.
90Sr activity was measured with the full spectrum DPM (FS-DPM) counting method after plotting the quench correction curves of 90Sr and 90Y, and the FS-DPM method was applied to determine the 90Sr in liquid waste samples. The optimum regions of 90Sr and 90Y were set for measuring 90Sr with the dual label DPM (DL-DPM) method. The direct measurement of purified 90Sr with spectrum unfolding techniq...
متن کاملUltrasound Assisted Emulsification Microextraction as a Simple Preconcentration Method for Determination of Atrazine in Environmental Samples
We represent an environmentally friendly sample of pre-treatment method, ultrasound assisted emulsification microextraction (USAEME) followed by gas chromatography nitrogen phosphorous detector (GC-NPD), to specify atrazine residues in environmental samples. Some parameters affecting the extraction efficiency such as the type and volume of the extraction solvent, emulsification time and additio...
متن کاملRapid method for homogenizing tissue samples for liquid scintillation counting.
EVALUATiON OF A new drug includes analysis of its tissue distribution. We have developed an improved method for solubilizing tissues that is not only rapid, but results in a homogeneous sample for counting. We had found that organs rich in connective tissue (heart, lung, skeletal muscle, urinary bladder, stomach, and intestinal wall) could not be completely disrupted by conventional techniques ...