Silica aerogel radiators for bunch length measurements
نویسندگان
چکیده
منابع مشابه
Single-shot electron-beam bunch length measurements.
We report subpicosecond electro-optic measurements of the length of individual relativistic electron bunches. The longitudinal electron-bunch shape is encoded electro-optically on to the spectrum of a chirped laser pulse. The electron-bunch length is determined by analyzing individual laser-pulse spectra obtained with and without the presence of an electron bunch. Since the length of the chirpe...
متن کاملBunch Length and Impedance Measurements at Spear3
Streak camera measurements were made at SPEAR3 to characterize longitudinal coupling impedance. For the nominal optics, data was taken at three rf voltages and a single-bunch current range of 0-20mA. Both bunchcentroid phase shift and bunch lengthening were recorded to extract values for resistive and reactive impedance. An (R+L) and a Q=1 model were then back-substituted into the Haissinski eq...
متن کاملELECTRON BEAM PROBE FOR THE BUNCH LENGTH MEASUREMENTS AT bERLinPro
For the successful operation of various accelerator facilities a detailed bunch characterization is required. A complete description can be achieved using various diagnostic systems installed along an accelerator beamline. Ideally the diagnostic should be able to measure parameters of a single bunch in a non-destructive manner. For bunch length measurements this results in a complicated task es...
متن کاملBunch Length Measurements in the SLC Damping Ring
The synchrotron light of the SLC damping ring was used to measure the bunch length with a streak camera at different times in the damping cycle. There are bunch length oscillations after injection, different equilibrium length during the cycle due to rf manipulations to avoid microwave instability oscillations, and just before extraction there is a longitudinal phase space rotation (bunch munch...
متن کاملBunch Length Measurements at Ttf Using Coherent Diffraction Radiation
The coherent diffraction radiation technique has been for the first time intentionally employed in the bunch length measurements at the TTF linac. Diffraction radiation (DR) is emitted as a beam passes through an aperture in a highly reflecting screen and, therefore, in contrast to transition radiation (TR), is a really non-intercepting tool a very attractive feature to diagnose high-power beam...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 2005
ISSN: 0168-9002
DOI: 10.1016/j.nima.2004.08.098