منابع مشابه
CMS Calorimeter Trigger/Readout Electronics for SLHC
The SLHC will be a very challenging environment for physics and for the trigger and DAQ in particular. Expected pileup multiplicies on the level of 40-200 interactions every beam crossing will flood the detector with the “ambient noise” of many low pT particles. The impact of these low pT particles is particular large for the hadron calorimeter, which has a relatively large cell size (compared ...
متن کاملGallium Arsenide - Based Readout Electronics
The readout of detector arrays requires the monolithic or hybrid integration of a integrate circuit multiplexer with the detector array. In most LWIR and VLWIR applications, a hybrid approach is used. For example, the detector array may be built from HgCdTe and the readout integrated circuit may be silicon CMOS [1]. The two integrated circuits are mated through a bump-bonding process in which e...
متن کاملReadout Electronics of the Na62 Gigatracker System
A crucial detector of the NA62 experiment is the beam spectrometer named Gigatracker. It consists of three stations of hybrid silicon pixels sensors with 150 ps (rms) of time resolution and 100 μm (rms) of space resolution. In addition the system operates under a high radiation environment and a high density of particles (up to 1.5 MHz/mm in the centre and 0.8 1 GHz in total). To meet these req...
متن کاملReadout Electronics for the ALICE Time Projection Chamber
In this paper we present the architecture of the Readout Electronics for the Time Projection Chamber (TPC) of the ALICE experiment at CERN LHC. The ALICE TPC electronics consists of 557568 channels. A single readout channel is made of two basic units: (a) an analogue ASIC (PASA) that incorporates the shaping/amplifier circuits for 16 channels; (b) a mixed-signal ASIC (ALTRO) that integrates 16 ...
متن کاملHigh-Accuracy Readout Electronics for Piezoresistive Tactile Sensors
The typical layout in a piezoresistive tactile sensor arranges individual sensors to form an array with M rows and N columns. While this layout reduces the wiring involved, it does not allow the values of the sensor resistors to be measured individually due to the appearance of crosstalk caused by the nonidealities of the array reading circuits. In this paper, two reading methods that minimize ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2020
ISSN: 1742-6588,1742-6596
DOI: 10.1088/1742-6596/1468/1/012113