Signal processing technique for non-invasive real-time estimation of cardiac output by inductance cardiography (thoracocardiography)
نویسندگان
چکیده
منابع مشابه
Impedance Cardiography for Cardiac Output Estimation
everal studies suggest the importance of cardiac power output calculation, which is derived from cardiac output (CO) and mean blood pressure, to predict the prognosis in heart failure patients not only in hospital but also in the outpatient setting.1–3 CO measured by the thermodilution method with a Swan-Ganz catheter placed in the pulmonary artery has become one of the most widely accepted and...
متن کاملPortable Impedance Cardiography System for Real-Time Noninvasive Cardiac Output Measurement
Impedance cardiography (ICG) is the only known method that can observe the continuous left ventricular volume changes non-invasively and conveniently. This paper proposes to develop a portable ICG system for long-term continuous cardiac activity monitoring using the impedance technique. This ICG system combines the advance analog amplifier with the calculation power of digital signal processing...
متن کاملA Real-Time Signal Processing Technique for MIDI Generation
This paper presents a new hardware interface using a microcontroller which processes audio music signals to standard MIDI data. A technique for processing music signals by extracting note parameters from music signals is described. An algorithm to convert the voice samples for real-time processing without complex calculations is proposed. A high frequency microcontroller as the main processor i...
متن کاملNon-invasive cardiac output monitoring.
Outcomes in the management of critically ill patients may be improved using goal-directed peri-operative haemodynamic monitoring. A conservative approach may no longer be acceptable but in view of the significant morbidity associated with balloon tipped flow directed pulmonary artery catheters a non-invasive approach would be preferable. In this review we consider the different non-invasive tec...
متن کاملNon-invasive measurement of cardiac output by a single breath constant expiratory technique.
A new single breath test has been developed that measures pulmonary blood flow (Qc) and pulmonary tissue volume by using the fact that Qc is proportional to the relationship between the absorption rate of acetylene (C2H2) from the alveolar gas and the rate of change of lung volume during constant expiratory flow. To make these measurements a bag in bottle system with a rolling seal spirometer, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical & Biological Engineering & Computing
سال: 2003
ISSN: 0140-0118,1741-0444
DOI: 10.1007/bf02348435