Signal Averaged Electrocardiography of Japanese.
نویسندگان
چکیده
منابع مشابه
Uncertainty principle of signal-averaged electrocardiography.
BACKGROUND Signal-averaged ECG (SAECG) reproducibility is reported to have a component that is independent of residual noise. Methods and Results-In group 1, multiple paired SAECGs were obtained to noise levels of 0.3+/-0.1 and 0.5+/-0.2 microV. For the 0.5- and 0. 3-microV noise recordings, QRS duration (QRSd) was 101.2+/-11.3 and 104.6+/-9.6 ms, respectively (P<0.0001), and the differences in...
متن کاملSignal averaged electrocardiography and renal function in hypertensive patients
Abnormal signal averaged electrocardiograms (SAECGs) and late ventricular potentials (LVPs) are predictors of sudden cardiac death. The present study hypothesized that SAECGs are impaired in hypertensive patients with renal failure. A total of 30 patients with grade 2 hypertension underwent SAECG. Serum level of creatinine and glomerular filtration rate (GFR) were also assessed. At least one SA...
متن کاملsignal-averaged electrocardiography in patients with advanced heart failure: a better indicator of left ventricular enlargement compared with conventional electrocardiography
background : the signal-averaged electrocardiography is a noninvasive method to evaluate the presence of the potentials generated by tissues activated later than their usual timing in the cardiac cycle. the purpose of this study was to demonstrate the correlation between the filtered qrs duration obtained via the signal-averaged electrocardiography and left ventricular dimensions and volumes an...
متن کاملSignal-Averaged Electrocardiography in Patients with Advanced Heart Failure: A Better Indicator of Left Ventricular Enlargement Compared with Conventional Electrocardiography
BACKGROUND The signal-averaged electrocardiography is a noninvasive method to evaluate the presence of the potentials generated by tissues activated later than their usual timing in the cardiac cycle. The purpose of this study was to demonstrate the correlation between the filtered QRS duration obtained via the signal-averaged electrocardiography and left ventricular dimensions and volumes and ...
متن کاملSignal-averaged electrocardiography and detection of heart transplant rejection: comparison of time and frequency domain analyses.
To evaluate the role of the signal-averaged electrocardiogram (ECG) in the detection of heart transplant rejection, findings on 277 ECGs were compared with those in 218 endomyocardial biopsy specimens in 25 patients followed up for a median duration of 5.2 months (range 7 days to 17.5 months). Signal-averaged ECGs obtained at intervals of 16.4 +/- 22.3 days were analyzed in the time domain befo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Heart Journal
سال: 1999
ISSN: 0021-4868,1348-673X
DOI: 10.1536/jhj.40.247