Side-to-side Antecubital Arteriovenous Fistulae for Haemodialysis
نویسندگان
چکیده
منابع مشابه
comparison of efficacy of side to side versus end to side arteriovenous fistulae formation in chronic renal failure as a permanent hemodialysis access
objectives the present study aimed to compare the efficacy rate of avfs using two different anastomosis methods; side to side (sts) versus end to side (ets) and to determine whether the different approaches render any preferences or complications. background in candidate patients for permanent hemodialysis or dialysis on a regular basis, an appropriate vascular access has great importance. the ...
متن کاملComparison of Efficacy of Side to Side Versus End to Side Arteriovenous Fistulae Formation in Chronic Renal Failure as a Permanent Hemodialysis Access
BACKGROUND In candidate patients for permanent hemodialysis or dialysis on a regular basis, an appropriate vascular access has great importance. The best permanent access is AVF (arterio venous fistula). Use of a technique to create AVF with better patency seems to be logical. OBJECTIVES The present study aimed to compare the efficacy rate of AVFs using two different anastomosis methods; Side...
متن کاملLigature versus transvenous endovenorrhaphy for closure of side-to-side arteriovenous fistula created for hemodialysis.
PURPOSE To report a novel technique for arteriovenous fistula (AVF) closure in side-to-side fistulas. MATERIALS AND METHODS One hundred and sixty-two patients with side-to-side AVFs, who were candidates for AVF closure, were randomly divided into two groups: group A (84 patients) who underwent AVF ligature and group B (78 patients) who underwent AVF closure using transvenous endovenorrhaphy t...
متن کاملComputational fluid dynamic evaluation of the side-to-side anastomosis for arteriovenous fistula.
OBJECTIVE The goal of this research was to compare side-to-side (STS) and end-to-side (ETS) anastomoses in a computer model of the arteriovenous fistula with computational fluid dynamic analysis. METHODS A matrix of 17 computer arteriovenous fistula models (SolidWorks, Dassault Systèmes, France) of artery-vein pairs (3-mm-diameter artery + 3-mm-diameter vein and 4-mm-diameter artery +6-mm-dia...
متن کاملکارآیی فیستولهای شریانی ـ وریدی side to side و end to side در مبتلایان به نارسایی مزمن کلیوی جهت همودیالیز
This article has no abstract.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BMJ
سال: 1974
ISSN: 0959-8138,1468-5833
DOI: 10.1136/bmj.3.5931.617