Should we abandon the APTT for monitoring unfractionated heparin?

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Establishing the heparin therapeutic range using aPTT and anti-Xa measurements for monitoring unfractionated heparin therapy

BACKGROUND Unfractionated heparin (UFH) has unstable pharmacokinetics and requires close monitoring. The activated partial thromboplastin time (aPTT) test has been used to monitor UFH therapy for decades in Korea, but its results can be affected by numerous variables. We established an aPTT heparin therapeutic range (HTR) corresponding to therapeutic anti-Xa levels for continuous intravenous UF...

متن کامل

Monitoring unfractionated heparin with the aPTT: time for a fresh look.

Laboratory monitoring is widely recommended to measure the anticoagulant effect of unfractionated heparin and to adjust the dose to maintain levels in the target therapeutic range. The most widely used laboratory assay for monitoring unfractionated heparin therapy is the activated partial thromboplastin time (aPTT). A fixed therapeutic range for the aPTT of 1.5 to 2.5 times the control value ha...

متن کامل

Accuracy of aPTT monitoring in critically ill patients treated with unfractionated heparin.

INTRODUCTION The anticoagulant effect of unfractionated heparin (UFH) is usually monitored by means of the activated partial thromboplastin time (aPTT). In critically ill patients, however, increased levels of acute phase proteins may decrease the accuracy of the aPTT, leading to inadequate UFH dosing. In these circumstances, the anti-Xa assay is recommended for monitoring. OBJECTIVE We aimed...

متن کامل

Should we abandon Kielland's forceps?

To assess the risks associated with the use of Kielland's forceps 2708 consecutive deliveries were studied prospectively and the neonatal outcome related to the mode of delivery. Of the 1191 primigravidas, 279 (23.4%) underwent instrumental delivery, of whom 65 (5.5%) were delivered with Kielland's forceps. There was no difference in early neonatal outcome (as judged by Apgar scores, intubation...

متن کامل

Should we abandon the theory theory ?

think if a human could not tell the difference between the computer’s behavior and the behavior of another human. In the standard Turing test, a human subject communicates with both another person and a computer electronically (e.g. by typing on a keyboard). The computer passes the Turing test if the subject cannot tell the computer’s communication from the human’s – if the computer can ‘fool’ ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Thrombosis Research

سال: 2017

ISSN: 0049-3848

DOI: 10.1016/j.thromres.2017.07.006