Short-Circuit Fault Current Calculation Method for the Multi-Terminal DC Grid Considering the DC Circuit Breaker

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Circuit Topology for Open Circuit and Short Circuit Fault Tolerant Dc - Dc Converter

This paper describes a new design for a fault tolerant Hbridge dc-dc converter. Open circuit and short circuit fault tolerance is achieved using multilevel converter topology in combination with pulse width modulation control strategy allowing a large set of converter switching states to produce bidirectional power flows at any required output voltage. If two switches fail at particular instant...

متن کامل

Derivation of the Cuk PWM DC-DC converter circuit topology

The DC transfer functions for the buck, boost, and Cuk PWM DC-DC converters in continuous conductionmodearell, l / ( l D ) , and-D/( l -D) respectively, ,where D is the duty cycle. Therefore. it is reasonable to expect that the Cuk PWh4 DC-DC converter circuit [l] can be synthesized by cascading boost and buck converter circuits. The purpose of this paper is to present a systematic and rigorous...

متن کامل

Decreasing Distribution Generation Effects on Grid Short Circuit Level Using Superconducting Fault Current Limiter Through Updating Relays Set-Points

Power system protection at transmission and distribution levels based on overcurrent relays is essential based on their properties such as detection, stability, high speed, backup and error correction accuracy. Since distributed generation sources are connected to the power grid, they not only increase the short circuit level of the grid, but also disrupt the set point of main and backup relays...

متن کامل

Low-Power CMOS Ramp Generator Circuit for DC-DC Converters

Ramp-signal generators are particularly critical in controlling the frequency and dutycycle of pulse-width modulated (PWM) switching supplies. They are normally implemented with a timed charging current source into a capacitor and a reset switch controlled by two comparators whose reference signals set the lower and upper limits of the ramp. A fast comparator is required to ensure the reset ope...

متن کامل

A Protection Circuit for DC-DC Converter with Voltage Doubler

This paper proposes a method to obtain a protected voltage gain by employing a protection circuit for the voltage doubler or multiplier circuit in an isolated tyde DC-DC Converter. The entire set up consists of a phase shift converter with a protected bridge/voltage doubler rectifier on the output side. The operating frequency of the phase shift converter is 20-25kHz (depending on the requireme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energies

سال: 2020

ISSN: 1996-1073

DOI: 10.3390/en13061347