Shielding effectiveness of X-ray protective garment
نویسندگان
چکیده
Purpose Certification of the X-ray shielding garment is based on attenuation testing flat material samples. We investigated difference effectiveness compared to realistic use when worn body a staff person. Methods Attenuation factors protective aprons have been evaluated for several clinical scenarios with Monte Carlo (MC) calculations ICRP female reference model and an experimental setup. The MC calculated refer effective dose E, whereas measured personal equivalent Hp(10). calculated/measured were identical materials under conditions standard IEC 61331-1 that currently in type aprons. Results As result, example, at common tube voltage 80 kV, real 0.35 mm Pb apron by 3-dimensional 38% 76% higher than MC-calculated organ doses show maximum contribution E being within operatoŕs abdomen/pelvis region. Conclusions With our findings, garments could be improved effectiveness.
منابع مشابه
Evaluation of X-ray protective shielding used in dental offices in Kerman, Iran, in 2014
BACKGROUND AND AIM: Protective equipment, such as lead aprons and thyroid shields, is effective in reducing patient radiation. This study was conducted for evaluation the use of thyroid shields and lead aprons in dental offices, in Kerman, Iran, in June 2014.METHODS: In this descriptive-analytical study, 106 dental offices with active X-ray machines were evaluated in Kerman. The information was...
متن کاملSurvey of the Use of X-ray Beam Collimator and Shielding Tools during Infant Chest Radiography
Background The use of shielding tools and X-ray beam collimator has extensively been advocated as effective methods to reduce radiation exposure to patients underwent radiological procedures. The aim of this study was to address the use of these protection measures during infant chest radiography. Material and Methods 348digital and/or analogue infant chest radiographs were reviewed that perfor...
متن کاملEvaluation of the Prevalence and Utility of Gonad Shielding in Pediatrics Undergoing Pelvic X-Ray
Background: Gonad shielding has been recommended during pelvic x-rays since the 1950s. The popular method of gonad shielding is placement a lead shield in the midline of the pelvis. The aim of this study was to evaluate the prevalence and utility of gonad shielding in pediatrics undergoing pelvic x-rays.Materials and MethodsFollowing study approval, we retrospectively retrieved data from the di...
متن کاملOutstanding X-ray shielding effects of carbon nanotubes
[Abstract] We report an outstanding phenomenon related to the X-ray attenuation induced by carbon nanotubes (CNTs). We observed that the mass attenuation coefficient of CNTs was significantly higher (> 100%) than that observed for highly oriented pyrolytic graphite (HOPG) and fullerenes (C60). The attenuation coefficient of CNTs increased by reducing the sample thickness. This attenuation pheno...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physica Medica
سال: 2021
ISSN: ['1724-191X', '1120-1797']
DOI: https://doi.org/10.1016/j.ejmp.2021.01.081