Shear strength of R/C bridge cantilever slabs
نویسندگان
چکیده
منابع مشابه
Improving the Punching Shear Strength of RC Slabs by FRP and Steel Sheets
This paper deals with the modeling of punching shear failure in reinforced concrete slabs using nonlinear finite element analysis. The 3D finite element analyses (FEA) were performed with the appropriate modeling of element size and mesh, and the constitutive modeling of concrete. The FE numerical models are validated by comparing with the experimental results obtained from tested specimens and...
متن کاملPunching shear strength of steel fibre reinforced concrete slabs
The ultimate strength of reinforced concrete slabs is frequently governed by the punching shear capacity, which may be increased with addition of traditional fitments such as reinforcing steel, headed studs or shear heads. In addition to these traditional methods of strengthening against punching, steel fibre reinforcement has proved to be an effective and viable alternative. The addition of fi...
متن کاملStrengthening of Bridge Slabs with Frp Systems
Advances in the fields of polymers and composites have resulted in a major development of high strength fibre reinforced polymers (FRP). These materials offer great potential for cost-effective retrofitting of concrete structures. In response to the growing need for concrete repair and rehabilitation, an experimental program was conducted at the University of Manitoba in Winnipeg, Manitoba, Can...
متن کاملSeismic Performance of Square RC Bridge Columns under Combined Loading including Torsion with Low Shear
During earthquake excitations, reinforced concrete bridge columns can be subjected to a combination of axial load, shear force, flexural moments, and torsional moments. The torsional moment can be much more significant in columns of bridges that are skewed, curved, have unequal spans, or unequal column heights. Combined loading including torsion can result in complex flexural and shear failure ...
متن کاملStress-Strain Field and Theoretical Analysis of RC Bridge
In this paper, a reinforced concrete(RC) bridge built in an interchange, in the city of Kerman (a city located in south of Iran) is examined by the Structural Health Monitoring (SHM) system. During the construction of this bridge such as; the main beams, slab, and retaining walls, some Electrical Strain Gauges were mounted on the main reinforcements at different locations within the body of thi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Engineering Structures
سال: 2008
ISSN: 0141-0296
DOI: 10.1016/j.engstruct.2008.04.017