Shanghai electron beam ion trap: design and current status

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Overview of the Electron Beam Ion Trap Program at NIST

This paper surveys the ongoing physics experiments at the Electron Beam Ion Trap (EBIT) facility at NIST, with particular attention paid to the underlying physical principles involved. In addition, some new data on the performance of our EBIT are presented, including results related to the determination of the trap width, ion temperature, and number of highly charged ions in the trap.

متن کامل

Simulating a Maxwellian plasma using an electron beam ion trap

We describe a technique for producing a Maxwell–Boltzmann electron energy distribution using an electron beam ion trap ~EBIT!. The technique was implemented on the Lawrence Livermore EBIT to simulate Maxwellian plasmas. We discuss technical and experimental issues related to these simulations. To verify the fidelity of the quasi-Maxwellian, we have measured line emission due to dielectronic rec...

متن کامل

An electron beam ion trap for the NSCL reaccelerator

The reacceleration of stopped fast-fragment beams or low-energy ISOL beams to the energy range of 0.3–12 MeV/nucleon allows for experiments such as low-energy Coulomb excitation and transfer reaction studies and for the precise study of astrophysical reactions. The coupling of a reaccelerator to a gas stopper at a fragmentation facility will provide rare isotope beams of nuclides not available ...

متن کامل

Tests of a Laser Ion Source at the Heidelberg Electron Beam Ion Trap

A laser ion source (LIS) has been designed and successfully tested for loading the Heidelberg electron beam ion trap (H-EBIT) with ions of practically all solid-state elements. A pulsed YAG:Nd laser (30 mJ, 8 ns) is used to produce plasma from a solid target. Lowly charged ions are extracted from the plasma and accelerated by a short high-voltage pulse, generating a pulsed ion beam with energy ...

متن کامل

Status of Electron Beam Ion Sources for Particle Therapy∗

The technical performance of ion sources of the Electron Beam Ion Source (EBIS) type has substantially improved during the last years. This is demonstrated by proof-ofprinciple experiments which have been done using a roomtemperature EBIS, a so-called Dresden EBIS-A, which has been in use for several years. A new superconducting EBIS, a so-called Dresden EBIS-SC, has been taken into operation. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Physics: Conference Series

سال: 2004

ISSN: 1742-6588,1742-6596

DOI: 10.1088/1742-6596/2/1/009