Shallow structure of the Landers Fault Zone from explosion-generated trapped waves
نویسندگان
چکیده
منابع مشابه
Low-velocity damaged structure of the San Andreas Fault at Parkfield from fault zone trapped waves
[1] We used dense linear seismic arrays across and along the San Andreas Fault (SAF) at Parkfield, California to record fault zone trapped waves generated by explosions and microearthquakes in 2002. Prominent trapped waves appeared at stations close to the SAF main fault trace while some energy was trapped in the north strand at the array site. Observations and 3-D finitedifference simulations ...
متن کاملMultiple-fault rupture of the M7.1 Hector Mine, California, earthquake from fault zone trapped waves
[1] We studied the complex multiple-faulting pattern of the 40-km-long rupture zone of the 1999 M7.1 Hector Mine, California, earthquake with fault zone trapped waves generated by near-surface explosions and aftershocks, and recorded by linear seismic arrays deployed across the surface rupture. The explosion excited trapped waves, with relatively large amplitudes at 3–5 Hz and a long duration o...
متن کاملEvidence of shallow fault zone strengthening after the 1992 M7.5 landers, california, earthquake
Repeated seismic surveys of the Landers, California, fault zone that ruptured in the magnitude (M) 7.5 earthquake of 1992 reveal an increase in seismic velocity with time. P, S, and fault zone trapped waves were excited by near-surface explosions in two locations in 1994 and 1996, and were recorded on two linear, three-component seismic arrays deployed across the Johnson Valley fault trace. The...
متن کاملFine structure of the landers fault zone: segmentation and the rupture process.
Observations and modeling of 3- to 6-hertz seismic shear waves trapped within the fault zone of the 1992 Landers earthquake series allow the fine structure and continuity of the zone to be evaluated. The fault, to a depth of at least 12 kilometers, is marked by a zone 100 to 200 meters wide where shear velocity is reduced by 30 to 50 percent. This zone forms a seismic waveguide that extends alo...
متن کاملVelocity contrast along the Calaveras fault from analysis of fault zone head waves generated by repeating earthquakes
[1] We systematically investigate the velocity contrast along the Calaveras fault that ruptured during the 1984 Morgan Hill earthquake using fault zone head waves (FZHW) that refract along the fault interface. We stack waveforms in 353 sets of repeating clusters, and align the peaks or troughs of the direct P waves assuming rightlateral strike-slip focal mechanisms. The obtained velocity contra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Geophysical Research: Solid Earth
سال: 1999
ISSN: 0148-0227
DOI: 10.1029/1999jb900194