SHAKING TABLE TESTS OF TWO-STORY WOOD FRAMES WITH OIL-DAMPERS
نویسندگان
چکیده
منابع مشابه
Seismic Behavior of Asymmetric Two-Story X-braced Frames
Concentrically braced frames (CBFs) are one of the efficient lateral load resisting systems in high seismicity regions. One of the common problems with the use of concentrically braced frames is limitation in the architectural application and position of the openings. Two-story X braced frames have more advantages than other configurations of concentrically braced frames, since in many cases th...
متن کاملAnalytical assessment of reinforced concrete frames equipped with TADAS dampers
In recent years, it is considerably attempted to develop the concept of energy dissipation as an applicable technology to overcome the energy released by earthquakes. The passive control systems such as metallic dampers have been widely considered. The dampers are basically used to mitigate the structural responses and reduce the damages in main structural elements by energy dissipation. ...
متن کاملShake Table Tests of Reinforced Concrete Flat Plate Frames and Post-tensioned Flat Plate Frames
A research study was undertaken to assess performance of flat plate systems constructed with slab shear reinforcement under dynamic loads. The research program consisted of shake table tests and accompanying analytical studies of two, approximately one-third scale, two-story, two-bay, slab-column frames. One specimen was constructed with reinforced concrete (RC) slab, whereas the other specimen...
متن کاملTHE SHAKING TABLE CONCENTRATOR: INFLUENCE OF TABLE PARAMETERS ON MANGANESE CONCENTRATION
Abstract: point of view. In this study, a shaking-table was used for concentrating a manganese ore sample from the Ghasem Abadarea in Kerman, Iran. Experiments were designed by using LThe influence of each variable and their interactions on the operation of the device was studied. The variables underinvestigation were: table slope, table frequency, water flowrate, feed rate, and particle size. ...
متن کاملAnalysis on Two Typical Landslide Hazard Phenomena in The Wenchuan Earthquake by Field Investigations and Shaking Table Tests.
Based on our field investigations of landslide hazards in the Wenchuan earthquake, some findings can be reported: (1) the multi-aspect terrain facing empty isolated mountains and thin ridges reacted intensely to the earthquake and was seriously damaged; (2) the slope angles of most landslides was larger than 45°. Considering the above disaster phenomena, the reasons are analyzed based on shakin...