SF6 high voltage circuit breaker contact systems under lightning impulse and very fast transient voltage stress

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SF6 High Voltage Circuit Breaker Contact Systems Under Lightning Impulse and Very Fast Transient Voltage Stress

In the past few years gas insulated high voltage circuit breakers have improved considerably, in particular with respect to required drive energy for operation, compactness and reliability. A further reduction in size implies increasing operational field stress inside the breaker and, thus, a reduction in built-in safety margins. If the design comes closer to its physical limits, in particular ...

متن کامل

degradation of oil impregnated paper insulation under influence of repetitive fast high voltage impulses

در طی سالهای اخیراستفاده ازمنابع انرژی تجدید پذیر در شبکه های مدرن بنا به دلایل زیست محیطی و اقتصادی به طور گسترده استفاده شده است همچون نیروگاههای بادی و خورشیدی .ولتاژتولیدی این نیروگاهها اغلب به فرم dc می باشد وادوات الکترونیک قدرت به عنوان مبدل و پل بین شکل موج dc وac استفاده می شوند.این پروسه باعث ایجاد پالسهایی برروی شکل موج خروجی می شود که می تواند وارد تجهیزات قدرت همچون ترانسفورماتور ی...

15 صفحه اول

Development of an Overall Condition Monitoring System of High Voltage SF6 Circuit Breaker

With the rapid development of arts of sensors and IT, on-line monitoring of circuit breaker is now desirable and practical for electric power utilities. This paper describes a set of overall on-line monitoring systems that was developed to control and monitor the condition of SF6 circuit breaker with different type of sensors and microcomputer based controller. The aim of the developed system i...

متن کامل

Low-voltage High-efficiency Fast-transient

(ABSTRACT) In order to meet demands for faster and more efficient data processing, modern microprocessors are being designed with lower voltage implementations. The processor voltage supply in future generation processors will decrease to 1.1 V ~ 1.8V. More devices will be packed on a single processor chip, and processors will operate at higher frequencies, beyond 1GHz. Therefore, microprocesso...

متن کامل

Transient Recovery Voltage Investigation in the Application of 15 kV Circuit Breaker Failure

Circuit breakers can fail to interrupt fault current when the power system has transient recovery voltage (TRV) characteristics that exceed the rating of the circuit breaker. There were two incidents of failures of outdoor switchgear at a power plant substation. The cause of the failure for these breakers was investigated in order to determine if transient recovery voltage is a contributing fac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Dielectrics and Electrical Insulation

سال: 2012

ISSN: 1070-9878

DOI: 10.1109/tdei.2012.6215088