Sevoflurane anaesthesia with an Oxford Miniature Vaporizer in vaporizer inside circle mode

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Diamedica Draw-Over Vaporizer: a comparison of a new vaporizer with the Oxford Miniature Vaporizer.

The Diamedica Draw-Over Vaporizer (DDV) has been developed as an alternative to the Oxford Miniature Vaporizer (OMV). Both can function as draw-over or plenum vaporizers. The performances of these two vaporizers were compared under conditions simulating intermittent positive pressure ventilation (IPPV) and continuous flow (CF). Series 1 experiments were conducted with the vaporizers in water ba...

متن کامل

Modification of a draw-over vaporizer for use with sevoflurane.

BACKGROUND Draw-over anaesthesia is widely used throughout the developing world, in disaster areas and in military anaesthesia when the supply of pressurized oxygen is unreliable. To date, no draw-over vaporizer has been able to deliver sufficient concentrations of sevoflurane for use in inhalation induction of anaesthesia. A laboratory study to assess the performance of a new vaporizer (DDV2) ...

متن کامل

Potentially fatal vaporizer incident.

EDITOR: We wish to report a potentially fatal critical incident that occurred during an elective operating theatre list. A similar problem [1] has been recently highlighted by the MHRA but without the emphasis of its potentially fatal nature (Fault in Draeger Vapor 2000/D-Vapor Vaporizer series with the interlocking device, MDA/2006/030) [2]. This series of vaporizers for isoflurane and sevo-fl...

متن کامل

A microprocessor-controlled anaesthetic vaporizer.

A microprocessor-controlled anaesthetic vaporizer is described. Fresh gas is mixed in the correct proportions using two pulsed solenoid valves and a proportion of this passes through a third pulsed solenoid valve and is bubbled through liquid halothane. The temperature of the liquid agent is measured and the pulse frequency is modified to give the correct vapour concentration for the set flow r...

متن کامل

The desflurane Tec 6 vaporizer.

A late development model of the Tec 6 vaporizer for the administration of desflurane vapour has been evaluated. It is heated electrically and has both electronic monitors of vaporizer function and alarms. The new filling system is a significant improvement over previous Tec filling systems. The vaporizer requires a warm-up period before it may be used, but when activated it provides an output t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: British Journal of Anaesthesia

سال: 1999

ISSN: 0007-0912

DOI: 10.1093/bja/82.4.557