Setups for Tomographic Imaging with Submillimeter Spatial Resolution
نویسندگان
چکیده
منابع مشابه
Spatial Resolution in Tomographic Imaging with Diffracted Fields
The spatial resolution that is achievable using non-uniformly sampled data in the Fourier domain is examined. In particular, we focus on the typical non-uniform sampling that arises when diffraction tomography is used. We firstly introduce an effective conversion from non-uniform to uniform sampling grids using a transformation that minimizes an error measure in the frequency domain and that is...
متن کاملHigh-resolution Millimeter Imaging of Submillimeter Galaxies
We present ~0.6” resolution IRAM PdBI interferometry of eight submillimeter galaxies at z~2 to 3.4, where we detect continuum at 1mm and/or CO lines at 3 and 1 mm. The CO 3-2/4-3 line profiles in five of the sources are double-peaked, indicative of orbital motion either in a single rotating disk or of a merger of two galaxies. The millimeter line and continuum emission is compact; we marginally...
متن کاملResolution enhancement in computerized tomographic imaging.
We consider the problem of reconstructing an object function f(r) from finitely many linear functional values. In our main application, the function f(r) is a tomographic image, and the data are integrals of f(r) along thin strips. Because the data are limited, resolution can be enhanced through the inclusion of prior knowledge. One way to do that, a generalization of the prior discrete Fourier...
متن کاملSubmillimeter continuum observations of Sagittarius B2 at subarcsecond spatial resolution
1 I. Physikalisches Institut, Universität zu Köln, Zülpicher Str. 77, 50937 Köln, Germany e-mail: [qin;schilke]@ph1.uni-koeln.de 2 Max-Planck-Institut für Radioastronomie, Auf dem Hügel 69, 53121 Bonn, Germany 3 California Institute of Technology, Cahill Center for Astronomy and Astrophysics 301-17, Pasadena, CA 91125, USA 4 Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambrid...
متن کامل3D Submillimeter-Resolution Reduced-Field-of-View Diffusion Tensor Imaging
Introduction For better delineation of neuronal architecture, higher spatial resolution is always desirable. Challenges in realization of high spatial resolution include but are not limited to long total scan time, low signal-to-noise ratio (SNR), and high sensitivity to T2* blurring, off-resonance, and motion-related artifacts. In the present work, the reduced field-of-view (rFOV) imaging appr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2014
ISSN: 1742-6596
DOI: 10.1088/1742-6596/517/1/012046