BACKGROUND Total analytical error has been a useful metric both to assess laboratory assay quality and to set goals. It is often estimated by combining imprecision (SD) and average bias in the equation: total analytical error = bias + 1.65 x imprecision. This indirect estimation model (referred to as the simple combination model) leads to different estimates of total analytical error than that ...

متن کامل

Analytical performance of free and total thyroxine assays.

Excessive bias and imprecision are major analytical problems associated with some assays for free and total thyroxine (T4). Bias in free T4 methods is largely proportional to variations in serum T4 binding. In direct methods, this is attributable to requirements for substantial quantities of protein-bound T4 to replace analytical losses of free T4. In some total T4 methods, bias is inversely pr...

متن کامل

Analytical performance and diagnostic accuracy of immunometric assays for the measurement of circulating oxidized LDL.

BACKGROUND Oxidized LDL (ox-LDL) plays an important role in the pathogenesis of coronary heart disease (CHD). Several tests for circulating ox-LDL have been published. We believe it is critical to carefully evaluate these assays because small differences in performance may have profound effects when results are compared; we therefore compared the analytical and clinical performances of 2 assays...

متن کامل

Current status and performance goals for serum thyrotropin (TSH) assays.

Current medical needs dictate that laboratories offer thyrotropin (TSH) assays that can reliably measure low TSH concentrations--a prerequisite for using the more cost-effective TSH-centered strategy currently recommended by the American Thyroid Association. This study reviews the functional performance of the TSH immunometric assay methods currently used in clinical practice. Methodological di...

متن کامل

Current status and performance goals for serum thyroglobulin assays.

Serum thyroglobulin (Tg) measurements are used as a tumor marker for monitoring patients with differentiated thyroid carcinoma. The clinical utility of six different Tg methods [RIA or immunometric assay (IMA)] currently used in Europe and the US was evaluated, with focus on methodologic standardization, sensitivity, interassay precision across the typical clinical monitoring interval (6 to 12 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Chemistry

سال: 2002

ISSN: 0009-9147,1530-8561

DOI: 10.1093/clinchem/48.6.919