Servo-Controlled Pneumatic Pressure Oscillator for Respiratory Impedance Measurements and High-Frequency Ventilation
نویسندگان
چکیده
منابع مشابه
Respiratory input impedance during high frequency oscillatory ventilation.
Total respiratory input impedance (Zrs) measured by forced excitation may be computed easily from pressure and flow measurements recorded at the airway opening. The purpose of this paper was to analyse how the information provided by Zrs may be used for monitoring ventilatory mechanics during high frequency oscillatory ventilation (HFOV). We measured impedance (0.125-32 Hz) in six dogs, and in ...
متن کاملVolume-guaranteed Ventilation Versus Pressure-controlled Ventilation in Preterm Infants with Respiratory Distress Syndrome: A Randomized Controlled Trial
Background: This study was targeted toward comparing volume-guaranteed (VG) ventilation with conventional pressure-controlled (PC) ventilation in preterm infants with respiratory distress syndrome (RDS) in terms of the facilitation of weaning and extubation and occurrence of complications, such as pneumothorax, intraventricular hemorrhage (IVH), retinopathy of prematur...
متن کاملHigh frequency pressure oscillator for microcryocoolers.
Microminiature pulse tube cryocoolers should operate at a frequency of an order higher than the conventional macro ones because the pulse tube cryocooler operating frequency scales inversely with the square of the pulse tube diameter. In this paper, the design and experiments of a high frequency pressure oscillator is presented with the aim to power a micropulse tube cryocooler operating betwee...
متن کاملTracheal pressure and impedance as determinants of gas exchange during high frequency ventilation.
This work explores the use of catheter pressure transducers to measure time averaged, mean squared pressure (MSP) in the trachea of anesthetized animals during high frequency ventilation using a prototype Emerson oscillator with a 25 ml stroke volume at 15 and 34 Hz. Tidal volume and MSP were varied by shunting a portion of the ventilator output for the study of the effect of driving pressure o...
متن کاملhigh frequency oscillatory ventilation in severe respiratory failure
despite improvement of mechanical ventilation devices for infants, lung injury still causes morbidity and mortality in many cases. to determine the effect of high frequency oscillatory ventilation (hfov) in infants with severe respiratory failure, 10 neonates were evaluated prospectively. mean gestational age of these patients was 35 weeks and alveolar-arterial oxygen gradient (a-ado2) and the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Annals of Biomedical Engineering
سال: 2004