Sequentially paced heterotopic heart transplant
نویسندگان
چکیده
منابع مشابه
Murine Heterotopic Heart Transplant Technique
It is now over forty years since this technique was first reported by Corry, Wynn and Russell. Although it took some years for other labs to become proficient in and utilize this technique, it is now widely used by many laboratories around the world. A significant refinement to the original technique was developed and reported in 2001 by Niimi. Described here are the techniques that have evolve...
متن کاملCoronary magnetic resonance angiography in heterotopic heart transplant recipient.
C oronary allograft vasculopathy remains the main limiting survival factor after heart transplantation and the major cause of mortality after the first year post-transplant, ultimately leading to graft loss. 1 Coronary x-ray angiogra-phy is the clinical gold standard and the most widely used diagnostic technique for coronary allograft vasculopathy in the majority of transplant centers. However,...
متن کامل3D-magnetic resonance angiogram of heterotopic heart transplant.
The patient is a 68-year-old man who had heterotopic heart transplantation (HHTx) performed 8 years ago for ischemic dilated cardiomyopathy. The patient presented for noninvasive evaluation of transplant cardiac function and patency of anastomotic connections. A contrast-enhanced 3Dmagnetic resonance angiogram (MRA) was performed, and the data reconstructed using a 3D volume-rendering technique...
متن کاملCASE REPORT ECG diagnosis of native heart ventricular tachycardia in a heterotopic heart transplant recipient
A case is reported of haemodynamic collapse in a 51 year old male heterotopic heart transplant recipient caused by native heart ventricular tachycardia. An accurate diagnosis was made by selective right and left sided electrocardiography. Synchronised electrical cardioversion of the native heart (200 J) resulted in restoration of sinus rhythm with prompt relief of symptoms and amelioration of t...
متن کاملECG diagnosis of native heart ventricular tachycardia in a heterotopic heart transplant recipient.
A case is reported of haemodynamic collapse in a 51 year old male heterotopic heart transplant recipient caused by native heart ventricular tachycardia. An accurate diagnosis was made by selective right and left sided electrocardiography. Synchronised electrical cardioversion of the native heart (200 J) resulted in restoration of sinus rhythm with prompt relief of symptoms and amelioration of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of Thoracic and Cardiovascular Surgery
سال: 1990
ISSN: 0022-5223
DOI: 10.1016/s0022-5223(19)36846-1