We developed a sequential injection analysis (SIA) method for the determination of iron in coastal, ground, and surface fresh waters using two different reagents (ferrozine and 1,10-phenathroline). The methodology uses a double-line SIA system to improve mixing conditions between sample and reagent solutions. A liquid waveguide capillary cell (LWCC) with 1.0 m pathlength, 550 μm i.d., and 250 μ...
متن کاملA multi-syringe flow injection system for the spectrophotometric determination of trace levels of iron in waters using a liquid waveguide capillary cell and different chelating resins and reaction chemistries
A method integrating a long waveguide capillary cell with a preconcentration resin in a multi-syringe flow injection analysis (MSFIA) system for iron determination in waters was developed. The determination of iron is based on a colorimetric reaction and two reagents were tested, ferrozine and ammonium thiocyanate. A liquid waveguide capillary cell (1.0 m pathlength, 550 μm i.d. and 250 μL inte...
متن کاملEnhanced sensitivity in flow injection analysis using a long pathlength liquid waveguide capillary flow cell for spectrophotometric detection.
Incorporation of a liquid waveguide capillary flow cell into a flow injection instrument enhances the sensitivity of flow injection analysis with spectrophotometric detection by two orders of magnitude. Nitrite determination at nM levels has been used to demonstrate the feasibility of this novel technique for trace analysis. Combining the long pathlength spectrophotometry with flow injection an...
متن کاملSpectrophotometric determination of zinc and copper in a multi-syringe flow injection analysis system using a liquid waveguide capillary cell: application to natural waters.
This work exploits a multi-syringe injection analysis (MSFIA) system coupled with a long liquid waveguide capillary cell for the spectrophotometric determination of zinc and copper in waters. A liquid waveguide capillary cell (1.0m pathlength, 550 μm i.d. and 250 μL internal volume) was used to enhance the sensitivity of the detection. The determination for both ions is based on a colorimetric ...
متن کاملDetermination of Nitrite and Nitrate in Natural Waters Using Flow Injection with Spectrophotometric Detection
A simple and sensitive flow injection spectrophotometric method is reported for the room temperature determination of nitrite and nitrate based on the Griess reaction and a copperised cadmium column for reduction of nitrate. Calibration graphs were linear over the range 2 – 1000 μg N L (R = 0.9997 and 0.9999, n = 9) with a limit of detection (3 s.d.) of 1.0 μg N L and relative standard deviatio...