Sequential Injection Analysis of Butyrylcholinesterase Using Butyrylcholine Ion-Selective Electrode Detector

نویسندگان

چکیده

A new automated analytical method for the determination of Butyrylcholinesterase (BChE) based on sequential injection analysis (SIA) using a butyrylcholine chloride (BuCh) ion-selective electrode (ISE) detector was developed. BuCh is degraded to choline and butyrate by enzymatic activity BChE, resulting in decrease concentration. By detecting this change concentration with BuCh-ISE, BChE can be determined indirectly. In present SIA BuCh-ISE α-cyclodextrin membrane, range 0.015–0.50 units/mL at 2.0 mmol dm−3 reaction time 5.0 min. The detection limit 4.8 × 10−3 units/mL.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sequential flow injection determination of chlorine species using a triiodide-selective electrode detector.

A flow injection analysis (FIA) method for the determination of four residual chlorine species, namely combined available chlorine (CAC), free available chlorine (FAC), total available chlorine (TAC) and chlorite (ClO2-) was developed using a flow-through triiodide-selective electrode as a detector. An important strategy of speciation studies utilized the kinetic discrimination of reactions bet...

متن کامل

Sequential injection analysis of thiocyanate ions using a microfluidic polymer chip with an embedded ion-selective electrode.

A sequential injection analysis (SIA) system for the determination of SCN(-) ion using a microfluidic polymer chip with an embedded SCN(-) ion-selective electrode (SCN(-)-ISE) as a detector was developed. Under the optimal flow conditions of the SIA system, the SCN(-)-ISE showed a good linear relationship between peak heights and logarithmic concentrations of SCN(-) ion with a Nernstian slope o...

متن کامل

Flow injection potentiometric determination of Fe ( III ) using a fluoride - selective electrode as detector *

Flow injection analysis (FIA) system incorporating a fluoride ion-selective electrode (FISE) as detector is described. Laboratory-built cascade flow cell equipped with FISE and reference electrode is used for flow injection potentiometric determination of Fe(III) based on monitoring of the formation of FeF2 in acid solution. Under optimized flow conditions (4.0 mL min–1, 300 μL samples, 10–5 mo...

متن کامل

Flow injection analysis of picric acid explosive using a copper electrode as electrochemical detector.

A simple and fast electrochemical method for quantitative analysis of picric acid explosive (nitro-explosive) based on its electrochemical reduction at copper surfaces is reported. To achieve a higher sample throughput, the electrochemical sensor was adapted in a flow injection system. Under optimal experimental conditions, the peak current response increases linearly with picric acid concentra...

متن کامل

Lanthanum(III) Ion Selective Electrode Based on a New Ionophore

A PVC membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(III) ion was prepared. This electrode revealedsuch a good selectivity toward La3+ ion over a wide variety of other metal ions. Some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Electrochemistry

سال: 2022

ISSN: ['2186-2451', '1344-3542']

DOI: https://doi.org/10.5796/electrochemistry.22-00095