Sequels after Implantation of Intraocular Collamer Lens
نویسندگان
چکیده
منابع مشابه
Intraocular pressure after implantation of the Visian Implantable Collamer Lens With CentraFLOW without iridotomy.
PURPOSE To compare the intraocular pressure (IOP) values during a 3-month period after implantation of the new Visian Implantable Collamer Lens (ICL; STAAR Surgical Company, Nidau, Switzerland) V4c design with CentraFLOW technology without iridotomy using a standard procedure followed by implantation of the conventional ICL V4b model. DESIGN Retrospective cohort study. METHODS This study in...
متن کاملImplantable Collamer Lens Versus Iris-Fixed Phakic Intraocular Lens Implantation to Correct Myopia: A Meta-Analysis
This study is a meta-analysis comparing the efficacy, predictability, and safety of correcting myopia via implantation of two types of phakic intraocular lens (PIOLs): the implantable collamer lens (ICL) and iris-fixed PIOL. The Cochrane library, Pubmed, and EMBASE were searched. Study selection, data exclusion, and quality assessment were performed by two independent observers. The pooled rela...
متن کاملPupil Diameter Changes in High Myopes after Collamer Lens Implantation
PURPOSE To observe the changes in pupil size under photopic and scotopic conditions after Implantable Collamer Lens (ICL) implantations in eyes with high myopia. METHODS The ICL was implanted in 90 eyes belonging to 45 patients with high myopia. Photopic pupil diameters, scotopic pupil diameters, anterior chamber depths, and ICL vaults were examined at the preoperative, postoperative 1-month,...
متن کاملPiggyback intraocular lens implantation to correct pseudophakic refractive error after segmental multifocal intraocular lens implantation.
PURPOSE To evaluate refractive and visual outcomes of secondary piggyback intraocular lens implantation in patients diagnosed as having residual ametropia following segmental multifocal lens implantation. METHODS Data of 80 pseudophakic eyes with ametropia that underwent Sulcoflex aspheric 653L intraocular lens implantation (Rayner Intraocular Lenses Ltd., East Sussex, United Kingdom) to corr...
متن کاملPiggyback intraocular lens implantation.
The piggyback method of implanting two intraocular lenses in one eye has been successfully expanded to address pseudophakic refractive error in normal eyes and eyes that have undergone post-penetrating keratoplasty. Piggyback implantation has been combined with the use of newly available minus-power lenses to provide appropriate power for a cataract patient with keratoconus, as well as to corre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Ophthalmology & Visual System
سال: 2015
ISSN: 2377-4290
DOI: 10.15406/aovs.2015.02.00049