Determination of sulfur in fossil fuels by isotope dilution electrothermal vaporization inductively coupled plasma mass spectrometry
The determination of S by solution nebulization quadrupole inductively coupled plasma mass spectrometry (ICP-MS) is dif®cult because of interferences from oxygen dimer ions. The large O2 z ion current from the solvent water is a serious interference at S, the most abundant of the four isotopes, and precludes its measurement. The isotopic composition of S varies in nature as a consequence of nat...
متن کاملSelective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry
In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...
متن کاملDetermination of titanium and vanadium in Ziegler-Natta catalysts by inductively coupled plasma atomic emission spectrometry.
A method for the determination of Ti and V using inductively coupled plasma atomic emission spectrometry (ICP OES) in Ziegler-Natta polymerization catalysts is proposed. The concentrations of both Ti and V are efficiently determined after catalyst acid digestion with a mixture of HNO3 + HCl + HF and heating (160 degrees C for 6 h) or with 10% (v/v) H2SO4 and heating (160 degrees C for 6 h) or w...
متن کاملDetermination of cadmium and lead in urine by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry.
Electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry (ETV-ID-ICP-MS) was applied to the determination of Cd and Pb in urine samples. The isotope ratios for each element in each analytical run were calculated from the peak areas of each isotope. A relatively low vaporization temperature was used, which separated the analyte from the major matrix components an...
متن کاملUltratrace determination of Pb, Se and As in wine samples by electrothermal vaporization inductively coupled plasma mass spectrometry.
The determination of Pb, Se and As in wine has a great interest due to health risks and legal requirements. To perform the analysis of wine, two considerations must be taken into account: (i) the low concentration level of the analytes; and (ii) the risk of interferences due to wine matrix components. The goal of this work is to evaluate electrothermal vaporization (ETV) sample introduction for...