Abstract One challenge in central hemodynamic monitoring based on electrical impedance tomography (EIT) is to robustly detect ventricular signal components and the corresponding EIT image region without external information. Current stimulation voltage measurement of were simulated with finite element porcine torso models presence a multitude thoracic blood volume shifts. The data was examined for linear dependence changes stroke volume. Based results information regarding sparse
منابع مشابه
4D geomechanical simulations for field development planning
3D and 4D geomechanical can be time-consuming to build and calibrate. However, once such a model is built, it is relative straightforward to use this model for various field development and management applications. In so doing, the return on the initial investment of time and effort in the creation of a 4D geomechanical model can be substantial. I present a case study where a 4D geomechanical m...
متن کاملImage Reconstruction using Simulated Annealing Algorithm in EIT
In electrical impedance tomography (EIT), various image reconstruction algorithms have been used in order to compute the internal resistivity distribution of the unknown object with its electric potential data at the boundary. Mathematically, the EIT image reconstruction algorithm is a nonlinear ill-posed inverse problem. This paper presents a simulated annealing technique as a statistical reco...
متن کاملMonitoring of the lung fluid movement and estimation of lung area using Electrical Impedance Tomography: A Simulation Study
Patients suffering from the acute respiratory distress syndrome (ARDS) requires thoracic electrical impedance tomography (EIT) for the monitoring their conditions ranging from dynamic shifting of body fluids to lung aeration right at the bedside. More objectively, EIT-derived numeric parameters would help the physician to evaluate the state of the lung. Thus, here we have performed a Finite Ele...
متن کاملA Level Set based Regularization Framework for EIT Image Reconstruction
Electrical Impedance Tomography (EIT) reconstructs the conductivity distribution within a medium from electrical stimulation and measurements at the medium surface. Level set based reconstruction method (LSRM) has gained attention during the last decade as an effective solution to address the need of reconstructing structures with limited amount of available data. The classical LSRM is based on...
متن کاملTemporal effects in EIT image reconstructions
Most EIT image reconstruction algorithms do not account for temporal effects such as non-instantaneous acquisition of data frames and temporal correlation between successive EIT images. We have recently published a framework for assessing the performance of reconstruction algorithms accounting for temporal effects. Results of applying this framework to five reconstruction algorithms and three t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Current Directions in Biomedical Engineering
سال: 2021
ISSN: ['2364-5504']
DOI: https://doi.org/10.1515/cdbme-2021-2222