Separating slow BOLD from non-BOLD baseline drifts using multi-echo fMRI

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel multi-echo fMRI weighting strategy using principal component analysis for BOLD contrast sensitivity enhancement

Introduction: In functional magnetic resonance imaging (fMRI), acquisition parameters must balance the tradeoffs between spatial coverage and resolution, temporal resolution, and signal contrast. Blood oxygenation level dependent (BOLD) fMRI studies commonly employ a 2D multi-slice T2*-weighted echo-planar imaging (EPI) acquisition to capture changes in T2* decay due to BOLD signal fluctuation,...

متن کامل

Source of nonlinearity in echo-time-dependent BOLD fMRI.

Stimulation-induced changes in transverse relaxation rates can provide important insight into underlying physiological changes in blood oxygenation level-dependent (BOLD) contrast. It is often assumed that BOLD fractional signal change (DeltaS/S) is linearly dependent on echo time (TE). This relationship was evaluated at 9.4 T during visual stimulation in cats with gradient-echo (GE) and spin-e...

متن کامل

High Resolution BOLD fMRI Using mHASTE

Introduction: Recently, a novel BOLD fMRI method based on a modified half Fourier single shot TSE technique, namely mHASTE, has been explored and discussed [1,2]. In comparison with the widespread EPI sequences (e.g. GEand SE-EPI), mHASTE offers artifactand distortion-free functional images, higher signal-to-noise ratio (SNR) and potentially better function specificity, while achieving comparab...

متن کامل

BOLD fMRI using a modified HASTE sequence

For more than a decade, turbo spin echo (TSE) pulse sequences have been suggested as an alternative to echo planar imaging (EPI) sequences for fMRI studies. Recent development in parallel imaging has renewed the interest in developing more robust TSE sequences for fMRI. In this study, a modified half Fourier acquisition single-shot TSE (mHASTE) sequence has been developed with a three-fold GRAP...

متن کامل

BOLD Noise Assumptions in fMRI

This paper discusses the assumption of Gaussian noise in the blood-oxygenation-dependent (BOLD) contrast for functional MRI (fMRI). In principle, magnitudes in MRI images follow a Rice distribution. We start by reviewing differences between Rician and Gaussian noise. An analytic expression is derived for the null (resting-state) distribution of the difference between two Rician distributed imag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: NeuroImage

سال: 2015

ISSN: 1053-8119

DOI: 10.1016/j.neuroimage.2014.10.051