Sentinel-2 MSI Radiometric Characterization and Cross-Calibration with Landsat-8 OLI

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sentinel-2 MSI Radiometric Characterization and Cross-Calibration with Landsat-8 OLI

Near-nadir observations by the Multispectral Instrument (MSI) onboard the Sentinel-2 and the Operational Land Imager (OLI) onboard Landsat 8 were collected during two Simultaneous Nadir Overpasses (SNO). Multispectral images with 10, 20, and 30 m resolution from a spatially uniform area in the Saharan desert were acquired for direct comparison of MSI and OLI TopOf-Atmosphere (TOA) reflectances....

متن کامل

The Ground-Based Absolute Radiometric Calibration of Landsat 8 OLI

This paper presents the vicarious calibration results of Landsat 8 OLI that were obtained using the reflectance-based approach at test sites in Nevada, California, Arizona, and South Dakota, USA. Additional data were obtained using the Radiometric Calibration Test Site, which is a suite of instruments located at Railroad Valley, Nevada, USA. The results for the top-of-atmosphere spectral radian...

متن کامل

Radiometric Cross-Calibration of GF-4 PMS Sensor Based on Assimilation of Landsat-8 OLI Images

Earth observation data obtained from remote sensors must undergo radiometric calibration before use in quantitative applications. However, the large view angles of the panchromatic multispectral sensor (PMS) aboard the GF-4 satellite pose challenges for cross-calibration due to the effects of atmospheric radiation transfer and the bidirectional reflectance distribution function (BRDF). To addre...

متن کامل

Sentinel-2A MSI and Landsat 8 OLI Provide Data Continuity for Geological Remote Sensing

Sentinel-2A MSI is the Landsat-like spatial resolution (10–60 m) super-spectral instrument of the European Space Agency (ESA), aimed at additional data continuity for global land surface monitoring with Landsat and Satellite Pour l’Observation de la Terre (SPOT) missions. Several simulation studies have been conducted in the last several years to show the potential of Sentinel-2A MSI (MultiSpec...

متن کامل

Radiometric Cross Calibration of Landsat 8 Operational Land Imager (OLI) and Landsat 7 Enhanced Thematic Mapper Plus (ETM+)

This study evaluates the radiometric consistency between Landsat-8 Operational Land Imager (OLI) and Landsat 7 Enhanced Thematic Mapper Plus (ETM+) using cross calibration techniques. Two approaches are used, one based on cross calibration between the two sensors using simultaneous image pairs, acquired during an underfly event on 29–30 March 2013. The other approach is based on using time seri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Advances in Remote Sensing

سال: 2017

ISSN: 2169-267X,2169-2688

DOI: 10.4236/ars.2017.62011