Sensorless Control of Doubly Fed Induction Generators Based on Rotor High-Frequency Signal Injection
نویسندگان
چکیده
منابع مشابه
Sensorless Model Reference Adaptive Control of DFIG by Using High Frequency Signal Injection and Fuzzy Logic Control
In this paper, a new sensorless model reference adaptive method is used for direct control of active and reactive power of the doubly fed induction generator (DFIG). In order to estimate the rotor speed, a high frequency signal injection scheme is implemented. In this study, to improve the accuracy of speed estimation, two methods are suggested. First, the coefficients of proportional-integral ...
متن کاملHybrid Fuzzy Reference Signal Tracking Control of a Doubly Fed Induction Generator
This paper presents a hybrid scheme for the control of active and reactive powers using the direct vector control with stator flux orientation (SFO) of the DFIG. The hybrid scheme consists of Fuzzy logic, Reference Signal Tracking (F-RST) controllers. The proposed (F-RST) controller is compared with the classical Proportional-Integral (PI) and the Polynomial (RST) based on the pole placement th...
متن کاملSensorless Sliding Power Control of Doubly Fed Induction Wind Generator Based on MRAS Observer
In this paper present a sensorless maximum wind power extraction for variable speed constant frequency (VSCF) wind power generation systems with a doubly-fed induction generators (DFIG), to ensure stability and to impose the ideal feedback control solution despite of model uncertainties , using the principles of an active and reactive power controller (DPC) a robust sliding mode power control h...
متن کاملModeling and Rotor Current Control of Doubly-fed Induction Machine with Complex Signal
AbstmctDoubly fed induction machine can he used for wind energy generation. The control of rotor currents can facilitate variable speed constant frequency operation at unity power factor. A model based on complex signal flow graph is developed. This leads to a physically insightful control strueturs of the machine. A rotor current control strategy based on the complex signal flow graph is devel...
متن کاملDynamic participation of doubly fed induction generators in multicontrol area load frequency control
This paper proposes a new control strategy to consider the doubly fed induction generator (DFIG) wind generation contribution in frequency control and regulation of multi-area interconnected power system when the wind power is the main generation of one area. Based on frequency requirements and system conditions, the proposed control approach determines whether to switch the wind generation int...