SENSOR FAULT ACCOMMODATION : APPLICATION TO AN ACTIVATED SLUDGE PROCESS
نویسندگان
چکیده
منابع مشابه
Sensor Fault Accommodation : Application to an Activated Sludge Process
The effect of changes in operating conditions due to fault occurrences can alter performances in industrial processes. One way of preventing performances from degradation is to modify the control law in order to maintain the functioning of the process under acceptable operating conditions. In this paper, a Fault Tolerant Control of an Activated Sludge Process is presented. Free fault data are r...
متن کاملApplication of Bioaugmentation Technology to Improve the Activated Sludge Treatment Process in Removal of Aromatic Compounds
This investigation was designed to evaluate the effects of bioaugmentation on maintaining the system stability under shock loading conditions, standardizing the <span style="font-size: 10pt; color: #00...
متن کاملAn LPV Approach to Sensor Fault Diagnosis of Robotic Arm
One of the major challenges in robotic arms is to diagnosis sensor fault. To address this challenge, this paper presents an LPV approach. Initially, the dynamics of a two-link manipulator is modelled with a polytopic linear parameter varying structure and then by using a descriptor system approach and a robust design of a suitable unknown input observer by means of pole placement method along w...
متن کاملExtended Luenberger Observer-Based Fault Detection for an Activated Sludge Process
In this paper, an observer-based fault detection and isolation (FDI) method for a biological wastewater treatment process (WWTP) is presented. The residual is generated utilizing an Extended Luenberger function observer. The FDI of a set of sensors faults is done by using a bank of Luenberger observers. The implementation of the proposed approach and the results obtained from its application to...
متن کاملMultivariable PID control of an Activated Sludge Wastewater Treatment Process
In general, wastewater treatment plant (WWTP) consists of several stages before it is released to a receiving water body. There are, preliminary and primary treatment (mechanical treatment), a secondary treatment (biological treatment) and a tertiary treatment (chemical treatment). In this chapter, since the work involve of identification and control design of activated sludge process to improv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IFAC Proceedings Volumes
سال: 2005
ISSN: 1474-6670
DOI: 10.3182/20050703-6-cz-1902.01864