Sensitive determination of total particulate phosphorus and particulate inorganic phosphorus in seawater using liquid waveguide spectrophotometry
نویسندگان
چکیده
منابع مشابه
Contribution of particulate phosphorus to runoff phosphorus bioavailability.
Runoff P associated with eroded soil is partly solubilized in receiving waters and contributes to eutrophication, but the significance of particulate phosphorus (PP) in the eutrophying P load is debatable. We assessed losses of bioavailable P fractions in field runoff from fine-textured soils (Cryaquepts). Surface runoff at four sites and drain-flow at two of them was sampled. In addition to di...
متن کاملPhosphorus distribution in sinking oceanic particulate matter
Despite the recognition of the importance of phosphorus (P) in regulating marine productivity in some modern oceanic systems and over long timescales, the nature of particulate P within the ocean is not well understood. We analyzed P concentration in particulate matter from sediment traps and selected core tops from a wide range of oceanic regimes: open ocean environments (Equatorial Pacific, N...
متن کاملParticle size distribution predicts particulate phosphorus removal
Particulate phosphorus (PP) is often the largest component of the total phosphorus (P) load in stormwater. Fine-resolution measurement of particle sizes allows us to investigate the mechanisms behind the removal of PP in stormwater wetlands, since the diameter of particles influences the settling velocity and the amount of sorbed P on a particle. In this paper, we present a novel method to esti...
متن کاملThe Determination of Inorganic and Organic Phosphorus in Meats
In 1906 Emmett and Grindleyl concluded from their investigations, that the Hart and Andrews2 method for the determination of inorganic and organic phosphorus in feeding stuffs, could not be used directly for determining these different forms of phosphorus in aqueous extracts of flesh, on account of the large quantity of soluble proteins present. They concluded, however, that if the soluble prot...
متن کاملLiquid core waveguide spectrophotometry for the sensitive determination of nitrite in river water samples.
A flow injection analysis system was built with a liquid core waveguide spectrophotometric detector using an 80 cm Teflon AF-1600 capillary tube (2,2-bistrifluoromethyl-4,5-difluoro-1,3-dioxole/tetrafluoroethylene). The system was applied to determine nitrite ion in river water samples. The lower limit of detection for nitrite was 2.1 nmol dm(-3) (0.1 ng dm(-3) as NO(2)(-)) and the relative sta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Talanta
سال: 2016
ISSN: 0039-9140
DOI: 10.1016/j.talanta.2016.02.058