Sensitive and selective detection of cesium via fluorescence quenching
نویسندگان
چکیده
منابع مشابه
Sensitive and selective detection of cesium via fluorescence quenching.
Herein we report a robust and easy method for detecting cesium metal ion (Cs(+)) in partially aqueous solutions using the fluorescence quenching of 2,4-bis[4-(N,N-dihydroxyethylamino)phenyl]squaraine. This squaraine dye was found to be both highly sensitive (low limits of detection) and selective (limited response to other metals) for cesium ion detection. The detection is likely based on the m...
متن کاملSensitive detection of copper ions via ion-responsive fluorescence quenching of engineered porous silicon nanoparticles
Heavy metal pollution has been a problem since the advent of modern transportation, which despite efforts to curb emissions, continues to play a critical role in environmental pollution. Copper ions (Cu2+), in particular, are one of the more prevalent metals that have widespread detrimental ramifications. From this perspective, a simple and inexpensive method of detecting Cu2+ at the micromolar...
متن کاملSelective detection of dopamine in the presence of ascorbic acid via fluorescence quenching of InP/ZnS quantum dots
Dopamine is a neurotransmitter of the catecholamine family and has many important roles, especially in human brain. Several diseases of the nervous system, such as Parkinson's disease, attention deficit hyperactivity disorder, restless legs syndrome, are believed to be related to deficiency of dopamine. Several studies have been performed to detect dopamine by using electrochemical analysis. In...
متن کاملPVP-coated graphene oxide for selective determination of ochratoxin A via quenching fluorescence of free aptamer.
In this paper, we developed a simple method to detect fungi toxin (ochratoxin A) produced by Aspergillus Ochraceus and Penicillium verrucosumm, utilizing graphene oxide as quencher which can quench the fluorescence of FAM (carboxyfluorescein) attached to toxin-specific aptamer. By optimizing the experimental conditions, we obtained the detection limit of our sensing platform based on bare graph...
متن کاملHighly efficient detection of hydrogen peroxide in solution and in the vapor phase via fluorescence quenching.
Herein we report the highly efficient and sensitive detection of hydrogen peroxide in both aqueous solution and in the vapor phase via fluorescence quenching (turn-off mechanism) of the amplified fluorescent conjugated polymer-titanium complex induced by hydrogen peroxide. Inter- and intra-polymer energy migration leads to extremely high sensitivity.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Dalton Transactions
سال: 2013
ISSN: 1477-9226,1477-9234
DOI: 10.1039/c3dt52215f