Semi-Functional Quantitative Flow Cytometry Assay for Lymphocytic Choriomeningitis Virus Titration
نویسندگان
چکیده
منابع مشابه
Semi-Functional Quantitative Flow Cytometry Assay for Lymphocytic Choriomeningitis Virus Titration
Quantitative PCR and plaque assay are powerful virological techniques used to measure the load of defective or infectious virus in mouse and human. However, these methods display limitations such as cross contamination and long run-time. Here, we describe a novel technique termed as semi-functional quantitative flow cytometry (SFQF) for the accurate estimation of the quantity of infectious lymp...
متن کاملImmunofluorescent cell-counting assay for lymphocytic choriomeningitis virus.
A quantitative assay for lymphocytic choriomeningitis virus was developed and standardized. The assay is based on direct immunofluorescent staining of infected L-929 cell monolayers and enumeration of cells containing fluorescent viral antigens. Maximal adsorption of virus to cells occurred within 1 h. Observations on the sequential development of viral antigens within cells showed that specifi...
متن کاملAccelerated and Improved Quantification of Lymphocytic Choriomeningitis Virus (LCMV) Titers by Flow Cytometry
Lymphocytic choriomeningitis virus (LCMV), a natural murine pathogen, is a member of the Arenavirus family, may cause atypical meningitis in humans, and has been utilized extensively as a model pathogen for the study of virus-induced disease and immune responses. Historically, viral titers have been quantified by a standard plaque assay, but for non-cytopathic viruses including LCMV this requir...
متن کاملLymphocytic Choriomeningitis Virus
There has been an upsurge of interest in lymphocytic choriomeningitis virus (LCMV) as a human pathogen and specifically as an underdiagnosed congenital infection (1,2). LCMV is a member of the Arenaviridae family of viruses. Arenaviruses have a complex life cycle involving chronic infection and shedding of the virus in rodents and episodic infections in humans (3,4). Six of the arenaviruses (La...
متن کاملFlow cytometry-based assay for titrating dengue virus.
Plaque assays for titrating dengue virus (DENV) are time-consuming and not suitable for strains that do not plaque. Fluorescence-activated cell sorting (FACS) has been used to detect DENV-infected cells. Here we describe a FACS-based assay for titrating DENV. We determined that at 24 h postinfection, the number of infected cells detected by FACS represented the first round of infection and ther...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Immune Network
سال: 2017
ISSN: 1598-2629,2092-6685
DOI: 10.4110/in.2017.17.5.307