Semi-Automatic Determination of Rockfall Trajectories

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Semi-Automatic Determination of Rockfall Trajectories

In determining rockfall trajectories in the field, it is essential to calibrate and validate rockfall simulation software. This contribution presents an in situ device and a complementary Local Positioning System (LPS) that allow the determination of parts of the trajectory. An assembly of sensors (herein called rockfall sensor) is installed in the falling block recording the 3D accelerations a...

متن کامل

Parametric evaluation of 3D dispersion of rockfall trajectories

The capability of evaluating and managing rockfall related risks is largely based on numerical modelling. Nevertheless, the reliability and accuracy of rockfall models is greatly affected by the strong uncertainty and spatial variability which characterise all the relevant parameters. In particular, 3D effects related to the variability of slope geometry and micro-topography play a major role i...

متن کامل

Simulation of rockfall trajectories with consideration of rock shape

The aim of the paper is to develop a fully 3D simulation technique for rockfall dynamics taking rock shape into account and using the state-of-the-art methods of multibody dynamics and nonsmooth contact dynamics. The rockfall simulation technique is based on the nonsmooth contact dynamics method with hard contact laws. The rock is modeled as an arbitrary convex polyhedron and the terrain model ...

متن کامل

Semi-automatic determination of elemental sulphur in rubber

Electro-active elemental sulphur dissolved in hydrazine hydrate solvent was studied by d.c. polarography, cyclic voltammetry and millicoulometry in sodium acetate, ammonium tartrate and sodium phosphate buffers in an aqueous medium. The method, which uses a mercury electrode, is highly sensitive with less interference than other polarographic methods. The method was extended to the determinatio...

متن کامل

Semi-automatic determination of lead in whole blood.

The procedure developed by Browett and Moss (1964) for the semi-automatic determination of the lead content of urine has been adapted for the determination of lead in blood. Determinations are normally carried out in duplicate on 2.0 ml. samples of whole blood and the minimum sample size is 0.5 ml. The organic substances present in blood are destroyed by a manual wet-oxidation procedure and the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensors

سال: 2014

ISSN: 1424-8220

DOI: 10.3390/s141018187