SEM study of simulated clinical use for four nickel–titanium rotary endodontic files
نویسندگان
چکیده
منابع مشابه
Surface finishing of unused rotary endodontic instruments: a SEM study.
During endodontic therapy, cleaning of root canals is performed using endodontic files and auxiliary chemical substances, and it is important that the endodontist be familiar with the instruments used in daily practice. This study evaluated, under scanning electron microscopy (SEM), the quality of the surface finishing of unused rotary endodontic instruments. Fifty sizes 20, 25 and 30 rotary fi...
متن کاملMechanical behaviour of nickel-titanium rotary endodontic instruments in simulated clinical conditions: a computational study.
AIM To develop an accurate finite element (FE) model for studying rotary endodontic instruments and to demonstrate the usefulness of the FE method in improving the knowledge of the mechanical behaviour of these instruments during root canal preparation. METHODOLOGY An accurate geometrical model of a Ni-Ti ProTaper F1 instrument was created. The interaction between the rotating instrument and ...
متن کاملDefects in rotary nickel-titanium files after clinical use.
The purpose of this study was to analyze the type and frequency of defects in nickel-titanium rotary endodontic files after routine clinical use, and to draw conclusions regarding the reasons for failure. All of the files (total: 378, Quantec Series 2000) discarded after normal use from a specialist endodontic practice over 6 months were analyzed. Almost 50% of the files showed some visible def...
متن کاملCyclic fatigue of Profile rotary instruments after simulated clinical use.
AIM The purpose of this study was to evaluate cyclic fatigue of Profile Ni-Ti rotary instruments (PRIs) after dry heat sterilization and up to 10 times simulated clinical use. METHODOLOGY Instruments of size 40-15 were used in a crown-down technique. Three groups were included in this study. In groups 1 and 2, each set of instruments was used in five and 10 canals, respectively. Group 3 was t...
متن کاملCyclic fatigue testing of three different rotary nickel titanium endodontic instruments in simulated curved canals - an in vitro sem analysis.
INTRODUCTION Instrument separation is a serious concern in endodontics. Stainless steel instruments usually deform before they separate whereas Nickel Titanium instruments do not show any sign of deformation. AIM of the present study was to compare the cyclic rotations needed to fracture three different rotary nickel titanium endodontic instruments namely Profile, K3 Endo, RaCe in simulated c...