SEM and EPMA Analysis of Spark Plug Electrode Erosion
نویسندگان
چکیده
منابع مشابه
Effect of electrode erosion on the required ignition voltage of spark plug in CNG spark ignition engine
In this article, the electrode erosion and the gap growth of spark plugs were measured on of a CNG fueled engine after durability tests. Then, the required ignition voltage and the spark quality were investigated by a spark plug test rig. Considering results of measurements, the gap growth increased as the running time increased. Thus, the gap growth of spark plugs with 200 and 280 hours runnin...
متن کاملAn Experimental Investigation of Spark Plug Temperature in Bi-fuel Engine and Its Effect on Electrode Erosion
Temperature is one of the effective parameters in erosion of spark plug electrodes. In this research, temperature of spark plug was measured in engine's different operation conditions with two types of fuels: compressed natural gas and gasoline. Test results showed that, temperature of center electrode is lower than ground electrode and maximum difference between them is 110ºC that occurs at...
متن کاملan experimental investigation of spark plug temperature in bi-fuel engine and its effect on electrode erosion
temperature is one of the effective parameters in erosion of spark plug electrodes. in this research, temperature of spark plug was measured in engine's different operation conditions with two types of fuels: compressed natural gas and gasoline. test results showed that, temperature of center electrode is lower than ground electrode and maximum difference between them is 110ºc that occurs ...
متن کاملElectrode Erosion in a High Energy Spark Gap*
The erosion rates for hemispherical electrodes, 2.5 em in diameter, made of graphite, copper-graphite, brass, two types of copper-tungsten, and three types of stainless steel have been examined in a spark gap filled with air or nitrogen at one atmosphere. The electrodes were subjected to 50,000 unipolar pulses (25 )ls, 4-25 kA, 5-30 kV, 0.1-0.6 Coul/shot) at repetition rates ranging from 0.5 to...
متن کاملSubmandibular gland sialolithiasis--sialographic and pathologic findings with evaluation using SEM and EPMA analysis.
Introduction Submandibular gland sialolithiasis is a common disease treated by oral surgery, and many case reports have been presented in the Japanese medical literature[1-31]. However, the observation of salivary stones by scanning electron microscopy and electron probe X-ray microanalysis has not been widely reported[25-31]. Recently, we treated four cases of submandibular gland sialolithiasi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Microscopy and Microanalysis
سال: 2005
ISSN: 1431-9276,1435-8115
DOI: 10.1017/s1431927605506652