Self-sufficient vibration sensor for high voltage lines
نویسندگان
چکیده
منابع مشابه
Sensor Temperature for a Low-Power Low-Voltage Self-Powered System Using Vibration Scavenging
This paper presents the conception of a Smart Low Power Temperature Sensor which is powered using ambient vibration energy. It is presented the architecture of the conception of the sensor to be implemented. This power system will be the main part of the power stage for a self-powered micro temperature sensor inside a distributed sensor network where accessibility to human being operators is ve...
متن کاملNanogenerator as self-powered vibration sensor
article as: A. Yu 006 Abstract Vibration is one of the most popular phenomena that exists in our daily life. Detection of mechanical vibration usually uses laser technology. Here, we demonstrated the first application of a piezoelectric nanogenerator (NG) as a self-powered sensor for detecting the vibration status of a cantilever. By attaching a NG at the surface of a cantilever near the fixed ...
متن کاملRadiofrequency exposure near high-voltage lines.
Many epidemiologic studies suggest a relationship between incidence of diseases like cancer and leukemia and exposure to 50/60 Hz magnetic fields. Some studies suggest a relationship between leukemia incidence in populations residing near high-voltage lines and the distance to these lines. Other epidemiologic studies suggest a relationship between leukemia incidence and exposure to 50/60 Hz mag...
متن کاملCharacteristic Analysis of DS18B20 Temperature Sensor in the High-voltage Transmission Lines’ Dynamic Capacity Increase
Dynamic capacity increase in high voltage electric power transmission line is currently the most economical method for solving electric power transmission bottleneck nowadays. DS18B20 temperature sensor is applied to the dynamic capacity increase of high voltage transmission lines to measure the conductor temperature and ambient temperature. The paper is focused on the experiment of DS18B20 bot...
متن کاملFault Locating in High Voltage Transmission Lines Based on Harmonic Components of One-end Voltage Using Random Forests
In this paper, an approach is proposed for accurate locating of single phase faults in transmission lines using voltage signals measured at one-end. In this method, harmonic components of the voltage signals are extracted through Discrete Fourier Transform (DFT) and are normalized by a transformation. The proposed fault locator, which is designed based on Random Forests (RF) algorithm, is train...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: tm - Technisches Messen
سال: 2020
ISSN: 2196-7113,0171-8096
DOI: 10.1515/teme-2020-0036