Self-adaptive thermal modulation of gas sensors
نویسندگان
چکیده
منابع مشابه
Micromechanical GaAs Thermal Convertor for Gas Sensors
This paper discusses design, simulation and fabrication of new Micromechanical Thermal Converters (MTCs) based on GaAs developed for Gas sensors. GaAs MTCs seem to be very attractive for design of thermally based MEMS sensor devices. High thermal isolation of these devices can be done by implementing of free micromechanical hot plates which is designed as thin as possible. Metal oxide gas senso...
متن کاملAn Adaptive Electronic Interface for Gas Sensors
This thesis focuses on the development of an adaptive electronic interface for gas sensors that are used in the NC State electronic nose. We present an adaptive electronic interface that allows for the accurate mapping of the sensor's voltage output to sensor resistance profiles. The adaptive interface uses a linearized Wheatstone bridge in a constant current configuration. The balancing of the...
متن کاملThermal characterization of a microheater for micromachined gas sensors
In this paper, a new four-point probe, double spiral heating element configuration for micromachined gas sensors is proposed and a simple analytical model of the steady-state thermal behavior of the microheater is presented. A testing procedure is suggested, based on simple two-wire and four-wire resistance versus power measurements, together with an iterative extraction procedure for the param...
متن کاملSurface-Micromachined Thermal Conductivity Gas Sensors For Hydrogen Detection
The undersigned hereby certify that they have read and recommend to the Fac-a thesis entitled " Surface-Micromachined Thermal Conductivity Gas Sensors for Hydrogen Detection " by Shuoxi Chen in partial fulfillment of the requirements for the degree of Master of Science.
متن کاملMulti-frequency Temperature Modulation for Metal-oxide Gas Sensors
This article presents an empirical study of temperature modulation for metal-oxide gas sensors at multiple frequencies ranging from 0.125Hz to 4Hz. Commercial metal-oxide sensors from two manufacturers were exposed to analyte concentrations below their isothermal discrimination threshold over a period of ten days. The results reported in this article indicate that temperature modulation can sig...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Procedia Engineering
سال: 2010
ISSN: 1877-7058
DOI: 10.1016/j.proeng.2010.09.071