Selectivity, Sensitivity and Detection Range in Ion-Selective Membrane-Based Electrochemical Potentiometric Sensors Analyzed With Poisson-Boltzmann Equilibrium Model
نویسندگان
چکیده
We present and validate an equilibrium model based on the Poisson-Boltzmann equations that includes main ingredients to simulate ion-sensitive membranes in context of electrochemical potentiometric sensors with without ionophores. With respect phase boundary models, our spatial resolution electrostatic potential concentrations. The enables study Nernstian non-Nernstian responses, helps improving detection range investigating selectivity cross-sensitivity issues related interferent ions sample solution. Therefore, is a useful support for design microelectronic optimizing relevant membrane features such as ionic sites ionophore concentration best sensitivity selectivity.
منابع مشابه
Polymer membrane-based ion-, gas- and bio-selective potentiometric sensors.
Recent progress in the design of new polymer membrane-based potentiometric ion-, gas- and bio-selective electrodes in chemistry laboratories at the University of Michigan (Ann Arbor) is reviewed. Emphasis is placed on describing the performance of devices for measuring anions (e.g., salicylate, thiocyanate, chloride and heparin) and gases (e.g., ammonia, carbon dioxide and oxygen) in biological...
متن کاملSquaramide-based tripodal ionophores for potentiometric sulfate-selective sensors with high selectivity.
A class of squaramide-based tripodal molecules was employed as new ionophores for highly sensitive and selective sulfate-selective sensors. Compared with the reported tripodal ionophore with urea, squaramide groups as superior hydrogen bonding donor were introduced into the tripodal structure to obtain new ionophores leading to better electrode performance. Three derivatives with unsubstituted ...
متن کاملScanning Electrochemical Microscopy. 19. Ion-Selective Potentiometric Microscopy
Potentiometric pH selective tips for scanning electrochemical microscopy (SECM) have been developed and used to image local pH changes in a variety of model chemical systems. Images of pH profiles around a platinum microelectrode during water reduction, a corroding disk of silver iodide in aqueous potassium cyanide, a disk of immobilized urease hydrolyzing urea, and a disk of immobilized yeast ...
متن کاملAn Electrochemical Sensor Based on Novel Ion Imprinted Polymeric Nanoparticles for Selective Detection of Lead Ions
In this study, the novel surface ion-imprinted polymer (IIP) particles were prepared and applied as a electrode modifier in stripping voltammetric detection of lead(II) ion. A carbon paste electrode (CPE) modified with IIP nanoparticles and multi-walled carbon nanotubes (MWCNTs) was used for accumulation of toxic lead ions. Various factors that govern on electrochemical signals including carbon...
متن کاملPotentiometric Based Membrane Sensor for Zinc Ion
A PVC-based membrane of 12-crown-4 exhibits good response for Zn2+ in a wide concentration range (7.08 10-5-1.00 10-1 M) with a non-nernstian slope of 20.5 mv per decade of concentration of Zn2+. The response time of sensor is <10 s and the membrane can be used for more than 3 months without observing any divergence. In addition, the proposed sensor exhibits very good selectivity for Zn2+ o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Sensors Journal
سال: 2022
ISSN: ['1558-1748', '1530-437X']
DOI: https://doi.org/10.1109/jsen.2022.3185168