Selective Harmonic-Compensation Control for Single-Phase Active Power Filter With High Harmonic Rejection

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Indirect Control of Single-Phase Active Power Filters using Harmonic Control Arrays

The ever increase of nonlinear loads in electric distribution networks causes many problems due to the high level of harmonic currents. This paper proposes a new technique for controlling a single phase shunt active power filter based on a selective compensation using the newly developed technique of harmonic control arrays. Simulation results confirm the appropriate selective harmonic compensa...

متن کامل

Power System Harmonic Compensation Using Shunt Active Power Filter

This paper shows the method of improving the power quality using shunt active power filter. The proposedtopic comprises of PI controller, filter hysteresis current control loop, dc link capacitor. The switching signal generation for filter is fromhysteresis current controller techniques. With the all these element shunt active power filter reduce the total harmonic distortion. Thispaper represe...

متن کامل

A Three-Phase Active Power Filter for Harmonic and Reactive; Power Compensation

In this paper, a 3-phase active power filter (APF) is presented to eliminate harmonics and to compensate the reactive power of an uncontrolled rectifier with capacitive loading taken as non-linear load. An APF is realized using 3-phase voltage source inverter (VSI) with dc bus capacitor. Reference source currents are estimated using P-I control over dc bus voltage and 3-phase source voltages. C...

متن کامل

Reactive Power Sharing and Harmonic Voltage Modification in Single Phase Island Micro-Grid with Drop Control

Abstract: When several parallel inverters are in islands operating mode, the droop control scheme is usually used to control the inverters. The droop control method enables the inverters of a Micro-Grid to control the voltage and frequency of the network in a decentralized regulation behavior. The drop control method also enables the inverters to share the required active and reactive powers of...

متن کامل

Selective Active Filter with Remote Harmonic Distortion Control

This paper presents the calculation methods for the different filtering blocks of a selective active filter in order to minimize the active filter inverter size, keeping the harmonic emissions at the limits stated by the applicable regulations. Since it may be necessary to comply with the regulations at a remote place with respect to the active filter location, the method has been extended to t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Industrial Electronics

سال: 2009

ISSN: 0278-0046

DOI: 10.1109/tie.2009.2024662