Selecting Mother Wavelet for Wavelet Analysis of On-Load Tap Changer Acoustic Emission

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Solid - State On Load Tap - Changer for Transformer Using Microcontroller

The on-load tap changing (OLTC) regulators have been widely used since the introduction of electrical energy. They ensure a good regulation of the output voltage in presence of large variations of the input voltage with typical response time from several mili-seconds to several seconds. Earlier mechanical type of on load tap changers were into practice. But they had considerable limitations and...

متن کامل

Wavelet analysis of acoustic emission signals in boring

Using acoustic emission (AE) signals to monitor tool wear states is one of the most e€ective methods used in metal cutting processes. As AE signals contain information on cutting processes, the problem of how to extract the features related to tool wear states from these signals needs to be solved. In this paper, a wavelet packet transform (WPT) method is used to decompose continuous AE signals...

متن کامل

Effect of Solid-State on Load Distribution Transformer Tap-Changer on Power Quality Enhancement

Recently electronic tap-changer has received more attention due to its quick response, better performance and simpler maintenance compared to the mechanical tap-changer. This paper presents the capability of the distribution transformer equipped with an electronic tap-changer for improving power quality. At this end, the analytical computation for determining the compensating limit of electroni...

متن کامل

Automobile Independent Fault Detection based on Acoustic Emission Using Wavelet

Wavelet transform is a well-known signal processing technique which has proven to be a successful technique in Non-Destructive Testing (NDT). Adopting this technique by Acoustic Emission (AE) method could result in better interpretation of data that are used for fault detection. In this study, AE signals emitted from automobile engines in both faulty and healthy conditions are analyzed using wa...

متن کامل

Innovative Transformer Load Tap Changer Control Using Ethernet-Based Communications

This paper describes the design of a load tap changer (LTC) control for up to four parallel transformers using a modified circulating current approach. The LTC control discussed in this paper was implemented using programmable logic, math functions, and IEC 61850 communications over fiber-optic Ethernet. One LTC control is associated with each transformer. The current angle from each LTC contro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Acta Physica Polonica A

سال: 2015

ISSN: 0587-4246,1898-794X

DOI: 10.12693/aphyspola.128.310