Seldinger technique chest drains and complication rate

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ImaGiNe Seldinger: First simulator for Seldinger technique and angiography training

In vascular interventional radiology, procedures generally start with the Seldinger technique to access the vasculature, using a needle through which a guidewire is inserted, followed by navigation of catheters within the vessels. Visual and tactile skills are learnt in a patient apprenticeship which is expensive and risky for patients. We propose a training alternative through a new virtual si...

متن کامل

Cricothyrotomy: Seldinger Versus Surgical Technique

Debate persists regarding whether cricothyrotomy is best performed using the Seldinger or conventional surgical technique (see JWEM Feb 2000, p. 11, and J Emerg Med 1999; 17:957). Investigators in Vienna provided a 60-minute training session consisting of lectures, slides, and the tools for each method to 20 ICU residents and fellows not experienced in cricothyrotomy. Each physician then perfor...

متن کامل

Neonatal diaphragmatic paralysis caused by chest drains.

A boy delivered at 32 weeks' gestation developed bilateral pneumothoraces that required multiple chest drains. He was dependent on the ventilator for 52 days because of bilateral diaphragmatic paralysis. Electrophysiological studies confirmed phrenic nerve damage. He eventually made a full recovery. It is likely that this damage was caused by the insertion of the chest drains.

متن کامل

Seldinger chest drain insertion: simpler but not necessarily safer.

http://thorax.bmj.com/content/65/1/5.full.html Updated information and services can be found at: These include: References http://thorax.bmj.com/content/65/1/5.full.html#ref-list-1 This article cites 7 articles, 6 of which can be accessed free at: service Email alerting box at the top right corner of the online article. Receive free email alerts when new articles cite this article. Sign up in t...

متن کامل

Extradural and subarachnoid catheterization using the Seldinger technique.

The Seldinger technique was developed using a plastic introducer through which introduction and manipulations of a silicone spinal catheter, an extradural stimulation lead or a small diameter fibreoptic scope are possible without the risk of damage to the vulnerable devices. It is not intended as a replacement of the standard technique of introducing a spinal catheter through a Tuohy needle in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Emergency Medicine Journal

سال: 2003

ISSN: 1472-0205,1472-0213

DOI: 10.1136/emj.20.2.169-a