SEISMIC RETROFITTING OF REINFORCED CONCRETE SHEAR WALL USING CARBON FIBER REINFORCED POLYMERS (CFRP)
نویسندگان
چکیده
منابع مشابه
Seismic Performance of Steel Plate-Reinforced Concrete Composite Shear Wall
In tall buildings the reinforced concrete (RC) shear wall is one of the predominant structural components used to resist lateral loads induced by earthquakes around the world. Previous research demonstrated that shear walls displayed a sudden loss in lateral capacity due to the wall corner and web crushing in the plastic zone. In addition, it was found that large shear distortions in shear wall...
متن کاملBond Development Between Carbon Fiber Reinforced Polymers and Concrete
Carbon fiber reinforced polymer (CFRP) sheets can be externally bonded for retrofit of concrete structures, improving flexure and sheer strength in the concrete. The key to CFRP sheets is the bond to the concrete, as bond is the means to transfer stress between the tow sheet and the concrete. Experimentation has been conducted to test a current market fiber-resin system, and to develop a resin ...
متن کاملShear strengthening of reinforced concrete beams with CFRP
The current paper reviews existing design guidelines for strengthening beams in shear with carbon fibre reinforced polymer (CFRP) sheets and proposes a modification to Concrete Society Technical Report TR55. It goes on to present the results of an experimental programme which evaluated the contribution of CFRP sheets towards the shear strength of continuous reinforced concrete (RC) beams. A tot...
متن کاملRetrofitting of Reinforced Concrete Beams with Steel Fiber Reinforced Composite Jackets
In the present study, a new method for retrofitting reinforced concrete beam is introduced in which steel-concrete composite jackets containing steel fiber is used. For this purpose, 75% of the peripheral surface of reinforced concrete beams was initially reinforced using steel plates and bolts, and steel fiber reinforced concrete was used between the steel plates and the peripheral surfaces of...
متن کاملHysteretic Behavior of Conventionally Reinforced Concrete Coupling Beams in Reinforced Concrete Coupled Shear Wall
This paper presents the experimental results of four full-scale coupling beams in which only horizontal reinforcements are placed, without diagonal reinforcements, with the aim to develop reinforcement details for coupling beams used in connecting side walls in a wall-slab structural system. Each coupling beam specimen was designed according to the deep-beam design procedure that does not use d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JOURNAL OF MECHANICS OF CONTINUA AND MATHEMATICAL SCIENCES
سال: 2020
ISSN: 0973-8975,2454-7190
DOI: 10.26782/jmcms.2020.12.00007