Seismic Response of RC Frames with a Soft First Story Retrofitted with Hysteretic Dampers under Near-Fault Earthquakes
نویسندگان
چکیده
Reinforced concrete (RC) frame structures with open first stories and masonry infill walls at the upper are very common in seismic areas. Under strong earthquakes, most of energy dissipation demand imposed by earthquake concentrates story, this eventually leads building to collapse. A efficient cost-effective solution for upgrading type structure consists installing hysteretic dampers story. This paper investigates response RC soft-story frames retrofitted subjected near-fault ground motions terms maximum displacements lateral forces compares them those obtained far-field earthquakes. It is found that similar levels total input energy, story caused earthquakes about 1.3 times larger than under while inter-story drift distribution values scarcely affected. concluded can be easily predicted from balance using appropriate parameter reflects influence impulsivity motion: so-called equivalent number cycles.
منابع مشابه
Evaluation of the Seismic Response of Single-Story RC Frames under Biaxial Earthquake Excitations
This paper summarizes the lessons learned from a full-scale test on two RC frame prototypes that have recently been tested on LNEC shaking-table using four pairs of biaxial synthetic ground motion records during 15WCEE Conference (2012). The reference structures are two single-story RC frames which are geometrically identical but with different reinforcement details. The simplified inelastic mo...
متن کاملResponse of Buildings with Inclined First-Story Columns to Near-Fault Ground Motion
In this paper a simple model of a three story building with inclined first-story columns has presented. The stories are supposed to be rigid and are connected to axially rigid mass less columns by elasto-plastic rotational springs and linear rotational dampers. The considered model is subjected to horizontal component of fault normal pulse with different magnitudes and the governed nonlinear di...
متن کاملPerformance Based Seismic Retrofit of Masonry Infilled Reinforced Concrete Frames Using Passive Energy Dissipation Devices
The paper presents a plastic analysis procedure based on the energy balance concept for performance based seismic retrofit of multi-story multi-bay masonry infilled reinforced concrete (R/C) frames with a ‘soft’ ground story using passive energy dissipation (PED) devices with the objective of achieving a target performance level of the retrofitted R/C frame for a given seismic hazard level at t...
متن کاملresponse of buildings with inclined first-story columns to near-fault ground motion
in this paper a simple model of a three story building with inclined first-story columns has presented. the stories are supposed to be rigid and are connected to axially rigid mass less columns by elasto-plastic rotational springs and linear rotational dampers. the considered model is subjected to horizontal component of fault normal pulse with different magnitudes and the governed nonlinear di...
متن کاملSeismic evaluation of reinforced concrete moment frames retrofitted with steel braces using IDA and Pushover methods in the near-fault field
One of the methods for retrofitting reinforced concrete moment frames is the use of steel braces. In this research, the seismic performance of a double-skinned concrete framing system reinforced with two concentric (CBF) and eccentric (EBF) steel bracing, was investigated under seven near-fault earthquake records of varying intensity. For this purpose, two ten-story concrete frames with five sp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Applied sciences
سال: 2021
ISSN: ['2076-3417']
DOI: https://doi.org/10.3390/app11031290