Seismic performance of four-storey masonry infilled reinforced concrete frame building
نویسندگان
چکیده
منابع مشابه
Seismic Performance of Reinforced Concrete Frames Infilled by Masonry Walls with Different Heights
This study carried out comparative seismic performance of reinforced concrete frames infilled by masonry walls with different heights. Partial and fully infilled reinforced concrete frames were modeled for the research objectives and the analysis model for a bare reinforced concrete frame was also established for comparison. Non–linear static analyses for the studied frames were performed to in...
متن کاملPerformance Based Seismic Retrofit of Masonry Infilled Reinforced Concrete Frames Using Passive Energy Dissipation Devices
The paper presents a plastic analysis procedure based on the energy balance concept for performance based seismic retrofit of multi-story multi-bay masonry infilled reinforced concrete (R/C) frames with a ‘soft’ ground story using passive energy dissipation (PED) devices with the objective of achieving a target performance level of the retrofitted R/C frame for a given seismic hazard level at t...
متن کاملexperimental investigation of masonry infilled reinforced concrete frame
an experimental study is conducted on three ½ scales, single-story, single-bay, frame specimens. the first specimen was a reinforced concrete frame with solid-brick infill. the second specimen was a reinforced concrete frame with hollow clay perforated-brick infill. the last specimen was a reinforced concrete frame without any infill. these three specimens were tested by pseudostatic method. di...
متن کاملAssessment of Masonry Infilled Reinforced-concrete Frames with Openings
Original scientific paper Reinforced-concrete (R/C) frames infilled with masonry wall, especially with the presence of an opening, are insufficiently explored structural elements. We have experimentally investigated influence of the opening’s type and position to the lateral response of reinforced-concrete frames with masonry infill. Correction factors, that take into account influence of the o...
متن کاملDynamic testing of a four-storey building with reinforced concrete and unreinforced masonry walls: prediction, test results and data set
This paper presents the results of a series of shake-table tests on a half-scale, four-storey building with reinforced concrete and unreinforced masonry walls. Due to the lack of reference tests, the seismic behaviour of such mixed structures is poorly understood. The test unit was subjected to several runs of increasing intensity yielding performance states between minor damage and near collap...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: MATEC Web of Conferences
سال: 2018
ISSN: 2261-236X
DOI: 10.1051/matecconf/201819502017