Seismic Performance of Existing Building Retrofitted with VSL-Gensui Damper

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seismic Mitigation of Building Frames using Magnetorheological Damper (TECHNICAL NOTE)

The present study focusses on the damping force control of shear mode magnetorheological (MR) damper for seismic mitigations. Therefore, the semi-active MR damper which can control the vibration is analyzed both experimentally and numerically. Carbonyl iron is used as the magnetic particle and Castrol Magnetec oil as carrier fluid throughout the study. MR damper is designed and fabricated, and ...

متن کامل

The Effect of Tuned Mass Damper on Seismic Response of Building Frames with Uncertain Structural Characteristics

Tuned mass dampers (TMDs) could be used to absorb the input energy of the applied load, and reduce the response of the building frames. However, the effectiveness of TMD in reducing the response of the building frames could be affected by inherited uncertainties in the structural characteristics of the frames. In this study, in order to investigate the probabilistic response of steel moment-res...

متن کامل

Seismic Performance of a Ductile Retrofitted Deck-truss Bridge

Seismic evaluations of many existing deck-truss bridges have revealed the vulnerability of their substructure and members of their superstructure. An innovative retrofit strategy developed by the authors includes replacement of the existing non-ductile end and lower-end bracing with ductile panels by incorporating energy dissipating devices to act as fuses, which can yield and dissipate energy ...

متن کامل

Evaluation of Seismic Performance and Effectiveness of Multiple Slim-Type Damper System for Seismic Response Control of Building Structures

This paper presents the evaluation of seismic performance and cost-effectiveness of a multiple slim-type damper system developed for the vibration control of earthquake excited buildings. The multiple slim-type damper (MSD) that consists of several small slim-type dampers and linkage units can control damping capacity easily by changing the number of small dampers. To evaluate the performance o...

متن کامل

Seismic Response Reduction of a Building Using Top-Story Isolation System with MR Damper

In this study, the adaptability of a semi-active top-story isolation system with an MR damper for reduction of seismic responses of tall buildings has been investigated. To this end, a 20-story building structure was selected as an example. Low damping elastomeric bearings and an MR damper were used to compose a smart top-story isolation system. Artificial earthquakes generated based on design ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Civil Engineering Dimension

سال: 2018

ISSN: 1979-570X,1410-9530

DOI: 10.9744/ced.20.2.86-90