Seismic Performance Evaluation of Masonry-Infilled Frame Structures using Equivalent Strut Models

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Masonry Infilled R.C.Frame with & without Opening Including Soft Storey by using “Equivalent Diagonal Strut Method”

Infilled frame structures are commonly used in buildings. Masonry infilled RC frames are the most common type of structures used for multi-storeyed constructions in the developing countries, even in those which are located in seismically active regions also. Masonry infill walls are mainly used to increase initial stiffness and strength of reinforced concrete (RC) frame buildings. In the presen...

متن کامل

Performance Based Seismic Retrofit of Masonry Infilled Reinforced Concrete Frames Using Passive Energy Dissipation Devices

The paper presents a plastic analysis procedure based on the energy balance concept for performance based seismic retrofit of multi-story multi-bay masonry infilled reinforced concrete (R/C) frames with a ‘soft’ ground story using passive energy dissipation (PED) devices with the objective of achieving a target performance level of the retrofitted R/C frame for a given seismic hazard level at t...

متن کامل

Seismic Performance of Reinforced Concrete Frames Infilled by Masonry Walls with Different Heights

This study carried out comparative seismic performance of reinforced concrete frames infilled by masonry walls with different heights. Partial and fully infilled reinforced concrete frames were modeled for the research objectives and the analysis model for a bare reinforced concrete frame was also established for comparison. Non–linear static analyses for the studied frames were performed to in...

متن کامل

Static Analysis of Masonry Infilled R.C.Frame With &Without Opening Including Soft Storey of Symmetric Building

Abstract: Masonry infill is considered as a non-structural element in all type of buildings where masonry use. But, masonry infill walls are mainly used to increase initial stiffness and strength of reinforced concrete (RC) frame buildings. This Open First storey is also termed as “Soft Storey”. The upper storeys have brick infilled wall panels with various opening percentage in it. In many cit...

متن کامل

experimental investigation of masonry infilled reinforced concrete frame

an experimental study is conducted on three ½ scales, single-story, single-bay, frame specimens. the first specimen was a reinforced concrete frame with solid-brick infill. the second specimen was a reinforced concrete frame with hollow clay perforated-brick infill. the last specimen was a reinforced concrete frame without any infill. these three specimens were tested by pseudostatic method. di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the Earthquake Engineering Society of Korea

سال: 2012

ISSN: 1226-525X

DOI: 10.5000/eesk.2012.16.1.047